Program 46-2 ~ 4 Overview - Toshiba Strata DK40 Programming Manual

Hide thumbs Also See for Strata DK40:
Table of Contents

Advertisement

Toll Restriction
Assigned by Class

Program 46-2 ~ 4 Overview

As many as four Toll Restriction classes can be defined for DK40 systems. Each class can be
set up to allow or deny specific STD and International codes and the same codes can belong
to more than one class. For each class, specific Local codes can also be assigned
46-6~8.
This program defines the STD and International codes allowed or denied for each Toll
Restriction class. The codes stored in memory can be viewed. These can be displayed by
using the 4 # command for each class, any code/s that is/are displayed are classed as allowed
codes. Anything not displayed by using the 4 # command is denied. Initialised data can be
seen at the bottom of the System Record sheet.
For each class, choose whether the table is used to record allowed STD/International codes in
memory (ALLOWED) or denied STD/International codes not in memory (DENIED). To
enter the STD and International codes the data programmed must not include the leading '0'
i.e. for 01932 only 1932 needs to be entered.
4-18
Program 46-2~4 Toll Restriction Allowed/Denied STD/International Codes
Strata DK40 Programming Manual Spring 1999
see Program

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents