Praesideo 3.5 | Installation and User Instructions | 11 | Optional Software

56.5 Main window

56.5.1 Opening the main window
Proceed as follows:
1 Double click on the Logging Server icon (see figure
56.2). A screen similar to the one in figure 56.4
appears.
Note
When server authentication (see section 56.7.5)
is enabled, the Logging Server asks for a user
name and a password.
figure 56.4: Main window
56.5.2 Status messages
The main window displays the status of the Logging
Server.
Message:
The Logging Server is OK.
Description:
The Logging Server operates correctly.
Recommended action:
----
Bosch Security Systems | 2011-02
Message:
Logging Server has no connection with <system>
Description:
There is no connection with the specified system.
Recommended action:
Make sure that the specified system is running and
that the specified system has an Ethernet connection
with the Logging Server.
Message:
Network controller <system> refused connection due
to incorrect user name or password.
Description:
It is not possible to connect to the specified system,
because the network controller authentication failed.
Recommended action:
Make sure the specified system knows the user name
and password of the Logging Server (see section
56.7.5.3).
Message:
The Logging Server options are changed. Restart the
Logging Server to use the changed settings.
Description:
The configuration settings of the Logging Server were
changed. The changed settings are not used until the
Logging Server is restarted.
Recommended action:
Restart the Logging Server to use the new settings.