9 Strip the red and brown insulations from the copper
wires by pushing them to the mechanical stop of the
stripping tool (tool 5, see figure 29.11).
figure 29. 1 1: Stripping a copper wire
Bosch Security Systems | 2011-02
29.4.6 Installing socket contacts
Proceed as follows:
10 Put a socket contact in the crimping tool (tool 3, see
figure 29.12). The upper part of the crimping tool
contains a ridge for positioning the socket contact in
the tool (see figure 29.13).
figure 29. 1 2: Crimping a socket contact (1)
figure 29. 1 3: Positioning a socket contact