ALARM LIST

ALARM lamp operation
1
If an alarm is triggered at a
multiplexer, timelapse VCR, or
camera, the ALARM lamp will
flash for five seconds and then
turn on.
If an alarm is triggered at a device, the
alarm contents are stored in a list at
the controller. Press the ALARM LIST
button to bring up the alarm list. The
list can hold up to 100 alarms.
2
Press the ALARM button.
Alarm contents will be displayed in the
order in which the alarms were
triggered.
Note:
The alarm list display will disappear if the ALARM
LIST button is pressed again while the alarm list is
being displayed.
The ALARM lamp will flash if there is an unconfirmed
alarm recording in the alarm list. The ALARM lamp
will be extinguished when the listed alarms are
confirmed.
A setting can be made from a connected device so
that the alarm list cannot be displayed in the menu
display section of the VSP-8000. Please refer to
your instruction manual for details.
Deleting the alarm list
1
Press the ALARM LIST button while holding down the
CLEAR button.
The alarm list deletion screen appears.
Note: Press the CLEAR button to abort the deletion and return to the
initial screen.
2
Press the ENTER button.
The alarm list is cleared and "NO ALARM" is displayed.
Press the ALARM LIST button again to return to the original
screen.
Note: If an alarm occurs before the clock has been set for the
VSP-8000, then the display of the alarm in the menu screen will
not have a time.
ALARM
(Flash → On)
ALARM LIST
A 0 0 1 - - / - - - - : - -
Example alarm list
(For multiplexers)
(For timelapse VCR)
(For cameras)
1 Alarm number
The higher the number, the newer the alarm. The alarm
number can be changed with the + (or – ) buttons.
2 Date and time of alarm
3 Device where alarm occurred
4 Channel of alarm
5 Type of alarm
EA: external alarm
VL: Video loss
SA: Sensor alarm
6 Alarm recording start and end
The alarm recording start (IN) and end (OUT) are entered in
the alarm list as two different events.
IN: Alarm recording start
OUT: Alarm recording end
Note: Dome cameras are not equipped with an alarm function.
+
CLEAR
ALARM LIST
ENTER
ALARM LIST
43
1
2
A 0 9 8 1 1 / 3 0 0 5 : 3 0
M X : 0 1 2
C H 1 6 E A
3
4
1
2
A 1 0 0 1 1 / 3 0 1 5 : 3 0
V R : 0 0 1
I N
3
6
1
2
A 0 9 7 1 1 / 3 0 0 3 : 0 0
C M : 0 0 1
3
A L A R M L I S T C L R ?
O K : E N T E R N O : C L R
N O A L A R M
5
E A
5

Hide quick links: