Removal (Fig. 43)
1. Position machine on a level surface. If ProPass is at-
tached to tow vehicle, apply tow vehicle parking brake,
stop engine and remove key from the ignition switch.
Chock wheels to prevent ProPass machine from mov-
ing.
2. Loosen conveyor belt tension:
A. Loosen cap screws (item 1) and flange nuts (item
2) that secure adjuster plates (item 3) and flange
bearings (item 6) to conveyor cover.
B. Loosen jam nuts (item 5) and flange head screws
(item 4) that adjust location of adjuster plates which
will loosen conveyor belt tension.
CAUTION
Before disconnecting any hydraulic compo-
nents, operate all hydraulic controls to relieve
system pressure and avoid injury from pressur-
ized hydraulic oil. See Relieving Hydraulic Sys-
tem Pressure in the General Information section
of this chapter.
3. Relieve hydraulic system pressure.
4. Clean conveyor motor and all hydraulic connections
at motor. Label hydraulic lines for assembly purposes.
5. Disconnect hydraulic hoses from hydraulic fittings on
conveyor motor. Allow hydraulic oil to drain from lines
into a suitable container. Put caps or plugs on open hy-
draulic lines and fittings to prevent contamination.
6. Support drive roller (item 15) to prevent it from shift-
ing.
7. Loosen set screw (item 16) that secures drive roller
to conveyor motor shaft.
ProPass 200
8. Remove two (2) flange head screws (item 19) and
lock nuts (item 18) that secure conveyor motor shaft to
conveyor cover.
9. Slide conveyor motor from drive roller and remove
motor and motor spacer (item 21) from machine. Locate
and retrieve woodruff key (item 20) from motor shaft.
10.If necessary, remove hydraulic fittings from conveyor
motor. Remove and discard O--rings from fittings.
NOTE: For conveyor motor service information, see
Rear Option Motor Service in this section.
Installation (Fig. 43)
1. If removed, install hydraulic fittings with new O--rings
into the conveyor motor ports (see Hydraulic Fitting
Installation in the General Information section of this
chapter).
2. Apply antiseize lubricant to conveyor motor shaft.
3. Place woodruff key (item 20) to slot in conveyor mo-
tor shaft. Position motor spacer (item 21) to motor flange
and then slide motor shaft into drive roller.
4. Align motor mounting holes with conveyor cover and
secure motor with two (2) flange head screws (item 19)
and lock nuts (item 18).
5. Apply Loctite #242 (or equivalent) to threads of set
screw (item 16). Tighten set screw to secure drive drum
to motor shaft.
6. Remove all caps or plugs that were placed on hy-
draulic hoses and fittings during disassembly.
7. Using labels placed during motor removal, correctly
install hydraulic hoses to hydraulic fittings on conveyor
motor. Tighten connections (see Hydraulic Hose and
Tube Installation in the General Information section of
this chapter).
8. Adjust conveyor belt (refer to conveyor belt tension-
ing procedure in ProPass 200 Operator's Manual).
Page 3 - - 45