e. OTHER FUNCTION VIA REMOTE COMMANDER
All the data becomes the values in memory.
7, -
All user control goes to the standard state.
8, -
[Display], - Service data initialization (Be sure not to use usually.)
Select Device or Category (Up, Down)
2, 5

3-2. ADJUSTMENT METHOD

Item Number 000 HPOS
This explanation uses H POSITION as an example.
1. Select "000 HPOS" with the
2. Raise/lower the data with the
3. Select the optimum state. (The standard is IF for PAL reception.)
4. Write with the [MUTING] button. (The display changes to WRITE.)
5. Execute the writing with the
SERVICE.)
Example on screen display :-
Use the same method for all Items. Use
then execute the write with
Note : 1. In [WRITE], the data for all items are written into memory together.
2. For adjustment items that have different standard data between 50Hz or 60Hz, be sure to use the respective input
signal after adjustment.
and
buttons, or
1
4
2
and
buttons.
3
6
button. (The WRITE display will be changed to red color while excuting, and back to
-
GEOM
000
HPOS
031
SUS01
3.50M
0001
1111
GEOM
000
HPOS
031
3.50M
0001
1111
SUS01
Write with [MUTING]
GEOM
000
HPOS
031
SUS01
3.50M
0001
1111
Write executed with -
and
to select the adjustment item, use
1
4
.
-
and
.
5
50
SERVICE
FF FF
NTSC3 65553
WRITE
50
FF FF
NTSC3 65553
WRITE
50
FF FF
NTSC3 65553
– 13 –
KV-SW292M50/M61/M80/N60
GREEN
Adjusted with 3
and 6 buttons.
GREEN
RED
The WRITE display
then the display
returns to green
SERVICE.
and
to adjust, write with [MUTING],
3
6
RM-GA002