STEP8: On the DTI/PRT/BRT cards, set the switches as follows to change the clock supply route from
1 to 0.
• 30DTI0/30PRT0 card: SW-1 to ON, SW-2 to OFF
• 30DTI1/30PRT1 card: SW-1 to OFF, SW-2 to ON
• 24DTI0/24PRT0 card: SW0-1 to ON SW0-2 to OFF
• 24DTI1/24PRT1 card: SW0-1 to OFF, SW0-2 to ON
• BRT0 card: SW0-2 to ON, SW0-3 to ON
• BRT1 card: SW0-2 to ON, SW0-3 to OFF
• 2BRT0 card: SW11-2 to ON, SW0-3 to ON
• 2BRT1 card: SW11-2 to ON, SW0-3 to OFF
• 4BRT0 card: SW4-1 to ON, SW4-2 to OFF, SW4-3 to OFF, SW4-4 to OFF and SW4-5 to ON
• 4BRT1 card: SW4-1 to ON, SW4-2 to OFF, SW4-3 to OFF, SW4-4 to OFF and SW4-5 to
OFF
– The CLK lamp on the MP card lights.
STEP9: Repeat the procedure shown in STEP 2 and STEP 3.
NOTE:
If noise periodically occurs, replace the MP card after checking the switch settings on the MP
card, and do the above test again.