SID to Terminating User-Display

[Australia/NZ/Asia/Latin America/UK]
To provide Calling Name Display for incoming calls from ISDN, assign the following data.
START
CM12
Assign Service Restriction Class A to each sta-
tion.
CM15
Allow Calling Name Display for incoming
calls in Service Restriction Class A assigned
by CM12 Y=02.
CM08
Specify the duration of displaying the name
when the incoming call is answered/the select
key for Calling Number Display and Calling
Name Display or CID key is pressed.
[Series 3300/3400/3500/3600 software
required]
NOTE:
Specify the duration of displaying the name
when the incoming call is answered/the select
key for Calling Number Display and Calling
Name Display or CID key is pressed.
[Series 3700 R12.2 software required]
Specify the duration of displaying the destina-
tion information when the outgoing call is an-
swered by the destination via ISDN.
[Series 3300 software required]
CM35
Provide the ISDN trunk route with Calling
Name Display for incoming calls.
A
DESCRIPTION
When using Series 3700 R12.2 soft-
ware or later, set the first data to
580.
CHAPTER 3 SYSTEM DATA PROGRAMMING
Y=02
(1)
X-XXXXXXXX: Station No.
(2)
XX ZZ
XX: 00-15 : Service Restriction Class A
Y=136
(1)
00-15: Service Restriction Class A as-
signed by CM12 Y=02
(2)
1 : Calling Name Display
(1)
537
(2)
0 : Until call is finished/key is pressed
again
1 : 6 seconds
(1)
580
(2)
0 : 6 seconds
1 : Until call is finished/key is pressed
again
(1)
538
(2)
0 : Until call is finished
1 : 6 seconds
Y=156
(1)
00-63: B channel Trunk Route No.
(2)
0: To provide
– 128 –