Philips SOPHO 2000 IPS User Manual page 309

Hide thumbs Also See for SOPHO 2000 IPS:
Table of Contents

Advertisement

SWITCH NAME
SW2
(Piano Key SW)
OFF
8
7
6
5
4
3
2
1
ON
SW3 (Dip SW)
OFF
1 2 3 4 5 6 7 8
SWITCH
SETTING
NUMBER
POSITION
ON
4
OFF
1-3, 5-8
OFF
1
OFF
2
ON
3
OFF
4
OFF
ON
5
OFF
ON
6
OFF
7
OFF
8
OFF
FUNCTION
Local loopback
For normal operation
Not used
Always set to OFF
Always set to ON
Not used (Always set to OFF)
Not used (Always set to OFF)
Common channel signaling data trans-
mission speed (For Digital Interface)
TRANSMISSION
SPEED
48 Kbps (1)
NOTE 3
48 Kbps (2)
NOTE 3
56 Kbps
64 Kbps
Not used (Always set to OFF)
Not used (Always set to OFF)
– 295 –
PN-DTB (CCH)
CHECK
SW
SW
3-5
3-6
OFF
ON
OFF
OFF
ON
OFF
ON
ON
Continued on next page
NWA-008852-001 Rev.5.0
98ch4002.fm
JULY/13/2007

Advertisement

Table of Contents
loading

Table of Contents