B
CM35
Specify whether the Type of Number/Number-
ing Plan Identification of CPN is provided, or
not.
[Series 3500 software required]
NOTE:
If this data is set to "1", the setting
data of CM35 Y=230/231 is invalid.
Specify the Type of Number for outgoing call.
Specify the Numbering Plan Identification for
outgoing call.
END
DESCRIPTION
CHAPTER 3 SYSTEM DATA PROGRAMMING
Y=234
(1)
00-63: B channel Trunk Route No.
(2)
0: To provide
Y=230 Type of Number
(1)
00-63: B channel Trunk Route No.
(2)
00: Unknown
01: International Number
02: National Number
03: Network Specific Number
04: ISDN Subscriber Number
06: Abbreviated Number
Y=231 Numbering Plan Identification
(1)
00-63: B channel Trunk Route No.
(2)
00: Unknown
01: ISDN/Telephony Numbering Plan
03: Data Numbering Plan
04: Telex Numbering Plan
08: National Standard Numbering Plan
09: Private Numbering Plan
– 155 –
ISDN FEATURE PROGRAMMING