BRI Programming Example:
The following is an example of common BRI Station Programming.
CM10 024>EF2125
025>EF2126
CM AC00> 000-2125
001-2126
CM
AC01> 000-1
001-1
CM
AC02> 000-1
001-1
CM
AC03> 000-1
001-1
CM
AC04> 000-1
001-1
CM
AC06> 000-1
001-1
CHAPTER 3 SYSTEM DATA PROGRAMMING
CM1B>2125, 0>2225*
2125, 1>2226
2
>None
7
2126, 0>2235*
2126, 1>2236*
2
>None
7
* Ext. 2225 and others assigned in CM1B are the Extension
numbers that should be entered into the BRI Terminals. Most
BRI Terminals require a 10 digits number.
If the BRI Terminals require a SPID
Only], it is common to add a 3 digits number to the main
number.
For example;
Main number (1): 214-555-2225
Main number (2): 214-555-2226
SPID (1)
: 214-555-2225123
SPID (2)
: 214-555-2226123
SPIDs are required for NI-1 protocol and AT&T Point-to-
Multipoint. Devices that are set as AT&T Point-to-Point do
not use SPIDs.