Mo unt in g the E nc los u re
The enclosure should be mounted via 4 (screws/bolts) through
the 4 mounting holes in the base. Ensure that the enclosure
is mounted on a solid, flat, vertical surface such that the base
will not flex when tightened. Enclosure dimensions are shown
below.
375
Figure 1 : Enclosure Dimensions
M odu l e Sp a c e s
Each enclosure has 4 identical module spaces and 1 large
module space that is allocated for non Bosch PCB boards (eg. a
securitel STU).
Each space includes 4 x 10mm stand-offs that the optional
expander PCB boards will mount using screws (screws will
be supplied with each board). The expander board will be
earthed via the screws that mount the PCB to the metal box.
All Bosch modules will mount on these module spaces.
A list of the PCB boards is detailed below
Module
Solution Control Panel
CM100 Voice Command Module
CM110 Output Expander
CM120 LAN Power Supply
CM130 RS232 Port Expander
CM140 GSM Modem Interface
CM150 TCP/IP Interface
Using the above table, the installer can determine how
many modules can be mounted in a single enclosure. On
some export models, module 3 will not be available as the
transformer mounts in this location.
Bosch Security Systems | 11/05 | BLCC110I
Installing the Hardware
90
Space Occupied
2 Adjacent Module Spaces
1 Module Space
1 Module Space
1 Module Space
1 Module Space
1 Module Space
1 Module Space
Figure 2: Metal Box – Module Space Allocations
Panel LE D Indicators
The Solution 64 PCB has two LED indicators (Dialler and Status
LED's) which display the following information.
Red Dialler LED
Condition
Off
On
Flashing
Table 1: Dialler LED Meanings
Green Status LED
Condition
Off
On
Flash Once Every 2 Seconds
Slow Flash
Flash Fast
Table 2: Status LED Meanings
i
During factory defaulting the Status and Dialler LED indicators
will be on steady for approximately 15 seconds.
Note
S e c t ion 2
Meaning
Offline
On Line (Dialling/Answered)
Incoming Call
Meaning
Error
Error
OK
Waiting for Direct Connect
AC or Battery Trouble
2-1