Notice of Liability While every precaution has been taken in the preparation of this document, neither Bosch Security Systems Pty Limited nor any of its official representatives shall have any liability to any person or entity with respect to any liability, loss or damage caused or alleged to be caused directly or indirectly by the information contained in this book.
Solution-16/Solution-16 Safecom Quick Reference Guide Introduction Thank you for choosing the Solution control panel for your installation. We are sure that you will find this system extremely flexible, reliable and easy to use. The quick reference guide is supplied with the system to provide users with enough basic information to wire, configure and program the system.
Copy Programming Key To Panel Memory Erase Programming Key Default System For Domestic Dialling Format Enable/Disable Automatic Stepping Of Locations When Programming Display Software Version (Hand Held Programmer Required) SOL 16 SAFECOM QUICK REF GUIDE.DOC.DOC Bosch Security Systems Pty Limited...
Solution-16/Solution-16 Safecom Quick Reference Guide Arming The System (On) Disarm All Areas (Partitioning) Enter your code followed by 0 and then the # key [eg. 2580 + 0 + #]. AWAY Mode Press and hold the # key until two beeps are This function allows a code to disarm all areas that heard.
Page 6
# key [eg. 2580 + 1 + #]. Enter the User Number that you want to add/change followed by the # key. Enter the New Code followed by the # key. SOL 16 SAFECOM QUICK REF GUIDE.DOC.DOC Bosch Security Systems Pty Limited...
Page 7
Solution-16/Solution-16 Safecom Quick Reference Guide Day Alarm – Toggle On/Off Codepad ID / Buzzer Tone (V1.10) Enter the Master Code followed by 7 and the Press and hold the 8 key until the desired # key [eg. 2580 + 7 + #].
Page 10
Zone 11 (Default = Instant) Zone Zone Zone Pulse Zone Pulse Event Code Event code Event Code Dialler Type Options Count Count Time Hundreds Tens Units Channel Digit Digit Digit SOL 16 SAFECOM QUICK REF GUIDE.DOC.DOC Bosch Security Systems Pty Limited...
Solution-16/Solution-16 Safecom Quick Reference Guide Location Zone 12 (Default = Instant) Zone Zone Zone Pulse Zone Pulse Event Code Event code Event Code Dialler Type Options Count Count Time Hundreds Tens Units Channel Digit Digit Digit Location Zone 13 (Default = Instant)
Page 12
To program the Pager ID Number, enter the decimal characters that represent the Pager ID Number. Remember to substitute a 10 for a zero and to terminate the number with a zero as you would if you were programming the telephone numbers. SOL 16 SAFECOM QUICK REF GUIDE.DOC.DOC Bosch Security Systems Pty Limited...
Page 13
Solution-16/Solution-16 Safecom Quick Reference Guide Location 540 - 623 Outputs Location 540 541 544 545 Location 546 547 550 551 Output 1 Output 2 Default = Event Polarity Time Time Base Default = Event Polarity Time Time Base BOSCHSAT Code...
‘OFF’ time. The ‘OFF’ time is the time base x the multiplier (Eg. If you want the output to pulse one (1) second ‘ON’ and five (5) seconds ‘OFF’, you would program time base as one (1) and the multiplier as five (5)). SOL 16 SAFECOM QUICK REF GUIDE.DOC.DOC Bosch Security Systems Pty Limited...
Page 15
Solution-16/Solution-16 Safecom Quick Reference Guide Location 624 - 625 Entry Time 1 Location 624 = Increments Of 1 Second (0 – 15 Seconds) 10 0 Location 625 = Increments Of 16 Seconds (0 – 240 Seconds) Location 626 - 627 Entry Time 2 Location 626 = Increments Of 1 Second (0 –...
Page 16
2 = Single Button Arming Allowed (AWAY, STAY Mode 1 & STAY Mode 2) 4 = Single Button Disarm Allowed (STAY Mode 1 or STAY Mode 2) 8 = Alarm Reset Memory On Disarm SOL 16 SAFECOM QUICK REF GUIDE.DOC.DOC Bosch Security Systems Pty Limited...
Solution-16/Solution-16 Safecom Quick Reference Guide Location 772 Safecom – RF Jamming Delay 0 = No RF Jamming Delay / 1 - 15 = RF Jamming Delay In Minutes (V2.00+) Location 773 Safecom RF Supervision Time 0 = No RF Supervision Time / 1 - 15 = RF Supervision Time In Minutes (V2.02+)
Page 20
Solution-16/Solution-16 Safecom Quick Reference Guide Connections For Split EOL Resistors For 16 Zone Operation Connections For Split EOL Resistors For 16 Zone Operation Using N/O Contacts Safecom Interface SOL 16 SAFECOM QUICK REF GUIDE.DOC.DOC Bosch Security Systems Pty Limited...