Output E v en t Ty p e Tab le
0 = Disabled
1 = Battery Trouble
2 = AC Trouble
3 = Telephone Line Trouble
4 = Comm Fail – Destination 1 / 2 P
5 = Third Dialler Attempt
6 = Destination 1 Reporting
7 = Destination 2 Reporting
8 = Destination 1 or 2 Kiss Off
9 = Destination 1 Kiss Off
10 = Destination 2 Kiss Off
11 = Dialler Disabled
12 = Output Device Missing
13 = Output Trouble
14 = Panel On Line
15 = Incoming Call
16 = System Trouble
17 = Box Tamper
18 = Zone Trouble
19 = Zone Mirror
20 = Zone Alarm
21 = Area Disarmed
22 = Area Armed (Any)
23 = Area All On
24 = Area Part On
25 = Area Part 2 On
Output De fa u lt Ta b le
The table below lists the default values for all Output parameters in the Solution 64. Outputs 1 to 3 are High current digital
outputs and Output 4 is the onboard relay output. Outputs 5 to 8 are available when the optional Output Relay Expander Board
(CM110) is fitted. Options marked N/A = Not Applicable.
Programming Option
Output Name
Event Type
Event Assignment
Output Polarity
Time Parameter
N° Of Hours
N° Of Minutes
N° Of Seconds
N° Of 1/10 Seconds
Output Options
Do not Operate If Low Battery
Display Output Overload
Report Output Overload
Display Missing Output Device
Report Missing Output Device
Reserved
Reserved
Reserved
Bosch Security Systems | 11/05 | BLCC110I
P
26 = Entry Time
P
27 = Exit Time
P
28 = End Of Exit Time
29 = Chime On
P
30 = Chime Zone Triggered
P
31 = Auto Arm Pre-Alert
P
32 = Ready To Arm All On
P
33 = Ready To Arm Part On
P
34 = Ready To Arm Part 2 On
P
35 = Closing Report Sent OK
P
36 = External Siren (Spk Beeps)
P
37 = Internal Siren (Spk Beeps)
O
38 = Alarm Any (silent or Audible ) A
P
39 = Fire Alarm
P
40 = Burglary Alarm
P
41 = Silent Alarm
P
42 = Duress Alarm
Z
43 = Keypad Medical
Z
44 = Keypad Fire
Z
45 = Keypad Panic
A
46 = Device Tamper
A
47 = Access Denied
A
48 = Strobe
A
49 = Smoke Sensor GND
A
50 = Sensor Watch
Table19: Output Event Types
Output 1
Output 2
Output 3
External
Strobe
Smoke
Siren
Light
Sensor PWR
36
48
(External
(Smoke
(Strobe)
Siren)
Sensor GND)
1
1
14
6
000
008
005
000
000
000
000
000
Y
Y
Y
Y
Y
Y
Y
N
Y
N
N
N
N
N
N
N
Table 20: Output Default Table
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Output 4
Output 5
Internal
Output 5
Siren
Name
49
37
(Internal
0
Siren)
1
1
1
11
6
0
000
000
000
000
005
000
010
000
000
000
000
000
Y
Y
N
Y
N/A
N/A
Y
N/A
N/A
N
N/A
N/A
N
N/A
N/A
N
N
N/A
N
N
N/A
N
N
N/A
Solution 64 | Installer Guide | Output Programming
51 = Senior Watch
52 = Exit Error
53 = RF Key Fob Function 1
54 = RF Key Fob Function 2
55 = Output Pre- Alert
56 = Follow PIN Code
57 = Part Entry Time
58 = Time Schedule
59 = Temperature Alarm
60 = Access Group
(A) = Area Event Assignment
(P) = Panel Event Assignment
(O) = Output Event Assignment
(Z) = Zone Event Assignment
(U) = User Event Assignment
(S) = Schedule Event Assignment
(G) = Access Group Event Assignment
(K) = Keypad
Output 6
Output 7
Output 6
Output 7
Name
Name
0
0
1
1
0
0
000
000
000
000
000
000
000
000
N
N
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
A
A
A
A
A
U
A
S
K
G
Output 8
Output 8
Name
0
1
0
000
000
000
000
N
N/A
N/A
N/A
N/A
N/A
N/A
N/A
8-9