Overview; Features; History Log - Bosch Solution 64 Installer's Manual

Intrusion control panel
Hide thumbs Also See for Solution 64:
Table of Contents

Advertisement

Fe a t ure s
Listed below are the main features of the Solution 64 Control
Panel.
Individual Box Tamper Circuit Monitoring
Voice Module With Multi-event Messages (Optional)
Report Via Email (Internet)
Telephone Line Busy Tone Detect
RAS Intelli-connect® CLI Caller Line Identification
Daylight Savings Auto Time Adjust
Senior Watch
System Maintenance Interval Reminder
System Weekly Test Reminder
Area Inactivity Interval
Temporary Pin Code
Dual Reporting
Alarm Report Abort/cancel Options
8 Programmable Holiday Calendars
8 Programmable Schedules
16 On-board Zones (Exp To 64 Wired or Wireless)
Fire Alarm Verification
48 Pin Codes
3 Supervised High Power Digital Outputs
1 Relay 2 Amp Form (C) Contact (Expandable to 13)
Supervised Siren Driver
Partitionable To 8 Areas
Dialler Reports SIA, Contact ID, SMS and Email Formats
Supervised LAN Keypads (Maximum 8 Keypads)
Keyswitch Input
256 History Event Memory
Fully Menu Text Programmable
Programmable Via Solutionlink Software(Remote/Direct)
Telephone Line Fail Monitor
Time Executed Functions
60 Output Event Types
Exit Restart
Expansion Module SuperSolution
DTMF Tone Decoder Built In
Remote and Auto Arming
Bosch Security Systems | 11/05 | BLCC110I
Ove rv iew
Zones
The Solution 64 control panel provides up to 64 separate zones
of protection. Zone programming determines the panel's
response to open/short and tamper conditions on the zone
loop.
Areas
The control panel supports up to 8 separate areas. You can
assign all zones to a single area, or you can assign each zone to
a combination of different areas.
You can arm and disarm the control panel by area,
alternatively, you can arm and disarm several areas at the same
time.
Dialler
The control panel has a built-in dialler to send reports to the
receiving party (ie. Security company monitoring station,
mobile phone etc).
Keypads
You can connect a maximum of 8 fully supervised keypads
to the control panel. The available current affects the total
number of keypads that you can connect without the need to
provide additional power supplies.

History Log

The control panel can store up to 256 history events from
all 8 areas. All events are stored in the log, even if they are
programmed not to report via the on-board dialler.
You can view the control panel's history log via keypad, serial
printer (optional), or by connection of a personal computer
(direct/remote) using the SolutionLink upload/download
software.
Programming
You can program the Solution 64 either by a keypad or using a
personal computer using the SolutionLink upload/download
software.
S e c t ion 1

Overview

1-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents