3.8

PROGRAM SYSTEM SPEED DIAL NUMBERS

The system list starts with 200 numbers (DCS Compact, DCS 24 & DCS 70) and 500 numbers (DCS)
and can be increased in blocks of 10. The maximum amount is 500 numbers if no more than 1000
station speed dial numbers are assigned on the DCS and no station speed dial numbers are assigned on
the DCS Compact. Speak to your Samsung Communications Specialist to increase or decrease the
system list.
Speed dial codes are 500 - 699 or 500 - 999. Each speed dial number consists of a line access code and
the telephone number to be dialled. The access code can be any line group, individual line, station group
or individual extension. The speed dial number can be up to 18 characters long including #, FLASH and
PAUSE.
NOTE: If Least Cost Routing (LCR) is being used, the LCR access code must be entered.
When you are entering a speed dial number, there are some special keys that you will need to use.
These are the last 6 programmable keys of the right hand row are known as A, B, C, D, E and F and are
defined below.
PROGRAM KEYS
UP & DOWN - Select the speed dial bin.
KEYPAD - Used to enter number.
HOLD - Press to clear entry.
ANS/RLS - Save data and advance to next program.
A - Does not have a function.
B - Inserts a FLASH.
C - Inserts a PAUSE.
D - Changes the dialling type from pulse to tone.
E - Hides and displays digits.
F - Toggles program between Station speed dial numbers and names
Open customer programming and follow the instructions below.
ACTION
1. Press TRSF 705
Display shows
2. Dial the speed dial bin desired (eg. 505)
OR press UP or DOWN to make a
selection and press the RIGHT soft key
to move the cursor
3. Enter the access code (eg. 0 - the
system automatically inserts a dash)
followed by the phone number (up to 18
digits long) and press the RIGHT soft to
return to step 2
4. Press the F key to toggle to program
System Speed Dial Names, step 3, to
enter the name
5. Press TRSF to store and exit
programming OR press SPEAKER to
store and advance to the next program
Page 7
DISPLAY
SYS SPEED DIAL
500 :
SYS SPEED DIAL
505 :_
SYS SPEED DIAL
505 :0-121223456789
SYS SPEED NAME
500 :_