Table 6-56: G2830 Programming Mode Options (Continued From Table 6-55) - Miele G1000 Technical Information

Miele dishwashers technical information
Table of Contents

Advertisement

G1000 / G2000 Dishwashers
Function
Resetting
standard settings
Wash/Final rinse
temperature
modification (from
software version
ID no. 984).
Main
wash
Final
rinse
Water quantity
normal /
increased
Sensor softener
activation /
deactivation,
water hardness
manual setting
Program running
time reduction
(from software
version ID no.
984)
Second interim
rinse selection
(from software
version ID no.
984)
Machine height
setting *2
Country variant
setting *2

Table 6-56: G2830 Programming Mode Options (Continued from Table 6-55).

Programming
Select Factory default. If all
parameters that can be
modified by the customer
(extras and settings) should be
reset to the standard settings,
press the OK touchpad.
Otherwise, press the Back
touchpad to go back one level.
Select Temperatures then
select the desired sub-menu.
Make the desired selection and
confirm with the OK touchpad
Make the desired selection and
confirm with the OK touchpad
Select Water plus. Make the
desired selection and confirm
with the OK touchpad
Select Water hardness. Make
the desired selection and
confirm with the OK touchpad
Select Shorten the program.
Make the desired selection and
confirm with the OK touchpad.
Select 2nd interim rinse. Make
the desired selection and
confirm with the OK touchpad.
Select Appliance height. Make
the desired selection and
confirm with the OK touchpad.
Select Country version. Make
the desired selection and
confirm with the OK touchpad.
195
Technical Information
Display
The display shows Reset factory
default settings?
The display shows the options Main
wash and Final rinse. This
increases the main wash or final
rinse temperature with a running
time extension.
The display shows the options
Normal and Increased
The display shows the options
Normal and Increased
The display shows the options
Normal and Increased
Automatic = sensor softener
activated. Alternatively the on-site
water hardness can be directly
selected. Setting range: 1°d to 70°d
(°d = Degree of German hardness).
See Table 6.2.
The display shows the options On
and Off (standard setting). This
offers a program-dependent running
time reduction by reducing
temperatures and/or canceling
holding times.
The display shows the options On
and Off (standard setting)
The display shows the options
Normal (G 1xxx) and XXL (G2xxx)
Setting options: EUR = Europe,
AUS = Australia, USA, JPN =
Japan, I/E = Italy/Spain, SER =
Southern Europe *3

Hide quick links: