Table 6-23: G1180 / G2180 Programming Mode Options (Continued On Table 6-24) - Miele G1000 Technical Information

Miele dishwashers technical information
Table of Contents

Advertisement

Technical Information
Flashing
Rhythm of
Function
Intake/Drain
Lt.
Pos. 0:
Long Short
Software
version ID
-
-
check
Pos. 1:
Long Short
Reset
-
1
Pos. 2: Set
the water
hardness
-
2

Table 6-23: G1180 / G2180 Programming Mode Options (Continued on Table 6-24)

Programming
Do not press the
The Sani-Wash
Program button.
LED is off or
The Intake/Drain
flashes. Shows the
LED is off.
software version ID
No., e.g. -769
Press the Program
The Intake/Drain
button 1x.
LED flashes 1x
briefly
To reset all
intermittently. With
parameters to the
this programming
delivery condition,
function, all
press the Program
parameters can be
button and hold
reset to delivery
until the
condition.
Intake/Drain LED
If the
flashes. Then press
SaniWash LED is
the Program button
off, the values do
briefly *2
not correspond to
the delivery
condition. If the
SaniWash LED
flashes, all values
are as in the
delivery condition.
Press the Program
The Intake/Drain
button 2x.
LED flashes 2x
briefly
To modify the water
intermittently.
hardness setting,
press the Program
The current setting
button to enter the
can be seen from
desired setting
the flashing rhythm
changes. *2
of the SaniWash
LED. If the LED
flashes 4x briefly
intermittently, this
indicates a factory
setting of 15-19
gr/gal.
140
G1000 / G2000 Dishwashers
Flashing Rhythm of
Indication
SaniWash LED
Long Short Display
-
Long Short Display
-
-
Long Short gr/gal
-
-
-
-
-
-
-
-
-
1
-
ID No.
P0
-
1
P1
1
1-5
2
6-9
3
10-14
4
15-19
5
20-25
6
26-31
7
33-38
8
39-45
9
46-63
-
64-88