Optima Series - G1470 & G2470; G1470 / G2470 Programming Mode - Miele G1000 Technical Information

Miele dishwashers technical information
Table of Contents

Advertisement

Technical Information
U13. Y38, reactivation valve:
The reactivation valve is activated for 60 sec.
U14. M2, fan:
The fan is activated for 60 sec.
U15. Vacant
U16. Vacant
U17. Vacant
6.4.2
Optima Series – G1470 & G2470
6.4.2.1

G1470 / G2470 Programming Mode

Initial requirements
1. Open the door.
2. Switch off the machine.
Accessing
1. Press and hold the program button.
2. Switch on the machine.
3. Release the program button when the decimal point is in the display.
4. Immediately press and release the program button 5 times and at the 5th time
hold until the Rinse & Hold LED flashes rapidly.
5. Release the program button.
If the Rinse & Hold LED has not started to flash within approx. 4 sec., the accessing
procedure must be repeated.
Acknowledgement Indicator
Successful accessing of the Service Dept. programming mode is indicated by a rapid
flashing Rinse & Hold LED (5 Hz)
Options
Refer to Tables: 6-38 through 6-42
G1000 / G2000 Dishwashers
.
162

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents