4.7 Configuration [1]
Feature Guide References
None
Flash—Flash Signal Detection (OPX)
Enables the PBX to detect the hookswitch flash signal from an SLT connected to OPX.
Default
Enable
Value Range
Disable, Enable
Programming Guide References
4.7.1 Slot [1-1]
Feature Guide References
None
Flash—Minimum BREAK Width (OPX)
Specifies the maximum length of the break signal in a flash signal from an SLT connected to OPX.
Default
200 ms
Value Range
8 × n (n=3–63) ms
Programming Guide References
4.7.1 Slot [1-1]
Feature Guide References
None
Flash—Flash Width (OPX)
Specifies the maximum length required by the PBX to recognize a hookswitch flash signal sent from an SLT
connected to OPX.
Default
800 ms
Value Range
8 × n (n=3–191) ms
Programming Guide References
4.7.1 Slot [1-1]