EPSON Stylus Pro 10000/10000CF
5.3.8.2 PF Motor
Perform the PF motor reliability test.
The motor is actuated designated number.
When the reliability number is [-1], reliability is repeated until key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times (within 8
column), and the count become 0 in the case that this is exceeded.
Following figure showing the PF motor reliability test menu sequence.
Movement distance is less
than 8.6mm
Speed
25 CPS
Acceleration speed
0.1G
Decrease speed
0.1G
Feed Amount : 0.1mm
Enter
Life Count : -1
Enter
Count :10
Enter
End : 50
Adjustment
Table 5-22.
Movement distance is more
than 8.6mm
52 CPS
0.2G
0.2G
Adjustable with "Paper Feed +/-" key
at unit of 0.1mm.
Adjustable with "Paper Feed +/-" key.
Figure 5-99.
o
The maximum value of the paper feed is [100.0mm].
o
The maximum value of the reliability number designation is [99,999,999 times].
o
When the [Pause] key is pushed during the reliability test, the test can be broken.
Self-Diagnostics
Revision B
267