EPSON Stylus Pro 10000/10000CF
(Clamp location)
(C362MAIN Board area)
(C362DRV Board area)
Figure 4-55.
When removing or replacing the FFC cables, always do so carefully.
Tearing or folding of the leads can damage the circuit boards. Check
the leads and never insert at an angle.
Disassembly & assembly
4.
Remove nine screws (CP(W) M3x6) securing the C362DRV board and remove the
board.
(Power Board area)
Disassembly Flow
Screw
Screw
Figure 4-56.
When removing/re-inserting the flat-cable (FFC) from/to a connector,
make sure to pull/insert the cable straight. Otherwise, internal contact
of the connector may be damaged and this causes a short-circuit to
destroy the electrical circuitries.
Lithium battery (CR2032:3V) is installed on the C362DRV board. Do
not short the C362DRV board with metal or conductive materials.
After replacing the C362DRV board, various adjustments are
required. For details about these adjustments, refer to Chapter 5,
Adjustment.