5.1.3 Adjustment Items

All parts that require adjustment when replaced are listed in the table below.
Table 5-2. Service Parts & Required Adjustments
Service
Operation
<Start-up the Self-diagnostics>
1. Head rank input (and initial ink charge)
2. Nozzle check
3. Head slant adjustment
Printhead
replacement
4. Bi-D adjustment
5. Head LR adjustment
6. Test print
7. Print head life counter clear
1. <Parameter backup> *1
2. <Reload firmware>
<Start-up the Self-diagnostics>
3. Ensure the capping position
4. Write D/A Value
5. Input head rank (Not necessary ink charge
initialize)
6. Bi-d adjustment
C362 DRV Board
replacement
7. Feed adjsutment
8. Paper feed adjsutment
9. Top & Bottom adjustment
10.Rear sensor position adjustment
11.Paper sensor adjustment
12. Test print
13.<Replace waste ink pads then clear the ink
counter.)
14.Write USB-ID
C362MAIN Board
<Reload firmware>
replacement
Adjustment
Adjustment Items
Refer to page
Refer to the
Paragraph 5.3
Refer to the
Paragraph
5.2.1,5.2.2,5.3
"Firmware
Upload" on
page 193
Table 5-2. Service Parts & Required Adjustments (continued)
Service
Operation
Sensor assembly
replacement
• P Front
• P Edge
CR Motor
replacement
PF Motor
replacement
Sensor assembly
replacement
P_REAR/P_Front/
P_EDGE
Sensor assembly
replacement
P Thick
Sensor assembly
replacement
Cover Sensor
*1: If you can backup the parameters, replace the main board and upload the parameters into the
new board. A successful backup means no adjustment is required using the self-diagnostic
function.
Adjustment Outline
Adjustment Items
<Start-up the Self-diagnostics>
1. Paper-Related Sensor adjustment
2. Top/bottom adjustment
1. <CR timing belt tension
adjustment>:Tension Gauge is required.
<Start-up the Self-diagnostics>
2. Bi-d adjustment
3. Top & Bottom adjustment
4. Test print
1. <PF timing belt tension
adjustment>:Tension Gauge is required.
<Start-up the Self-diagnostics>
2. Feed adjsutment
3. Top & Bottom adjustment
4. Rear sensor position adjustment
5. Test print
<Start-up the Self-diagnostics>
1. Sensor adjustment
<Start-up the Self-diagnostics>
From the "Test" menu select "Sensor" and then
"Paper Thickness"
Required tool: Filler Gauge
<Start-up the Self-diagnostics>
From the "Test" menu select "Sensor" and then
"Cover"
Revision B
Refer to page
Refer to the
Paragraph 5.3
Refer to the
Paragraph
5.2.3.1
Refer to the
Paragraph
5.2.3.2
Refer to the
Paragraph 5.3
Refer to the
Paragraph 5.3
Refer to the
Paragraph 5.3
190

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents