The follows are explanation on the setup example 1 to 6 in the table.
1. Spot (S) Setup example 1
When an Alarm is activated, it is able to display the desired camera picture on the desired monitor.
Example 1 shows:
An Alarm 1 is activated, Monitor 1 displays Camera 1 picture at preset 1 position.
After the above an Alarm 2 is activated, Monitor 1 switches and displays Camera 2 picture for 5 seconds.
Then Monitor 1 displays Camera 1 picture again for 10 seconds, after that Monitor 1 displays both camera's pictures alternately.
Memo
• It is recommended to program in advance as a Tour Sequence if plural Spot Cameras are assigned to a monitor by activating
an alarm.
• The following setup is used to maintain the latest alarmed Spot picture on a Monitor.
1. Set the both Dwell time and Auto Reset time to 30 seconds.
The previous Spot picture may appear in a moment in case that plural alarms are activated for a short period of time.
2. Set the Auto Reset time shorter than the Dwell time.
The alarm mode will be reset and Sequence or Spot picture will be displayed in case that the Auto Reset time reaches to
Off before activating the following Alarm.
2. Tour (T) Sequence Setup example 2
When an Alarm is activated, it is able to run a desired Tour Sequence on the desired monitor if the Tour Sequence is programmed
in advance.
Example 2 shows:
An Alarm 3 is activated, Tout Sequence 1 runs on Monitor 2
3. Group (G) Sequence Setup example 3
When an Alarm is activated, it is able to run the desired Group Sequence on the assigned monitor if the Group Sequence is pro-
grammed in advance.
5
Example 3 shows:
An Alarm 4 is activated, Group Sequence 1 runs on Monitor 3 and 4.
Important
The Monitors used for Group Sequence should be assigned in setup programming before.
4. Combination Setup example 4
When an Alarm is activated, it is able to activate the plural functions combined program in advance.
Example 4 shows:
An Alarm 5 is activated, Monitor 5 displays Camera 3 picture at preset 2 position. At the same time, Tour Sequence 2 runs on
Monitor 2 and Group Sequence 2 runs on Monitor 7 and 8.
5. Error (E) display
An "E"(Error) will appear in the table if an attempt is made to assign an incompatible mode to a monitor.
For example,
• Error(E) Setup example 5
An attempt is made to assign a Tour (T) Sequence 3 to Monitor 9 that is designated as a Spot monitor.
• Error(E) Setup example 6
An attempt is made to assign plural sequences to a monitor.
The one of attempts is valid and the others are not valid.