• Indirect connection between the Control Board and System Controllers ("Daisy-Chain" Type Wiring)
In this type of installation only one control cable directly connects between System Controller #1 and the Control Board. The
rest of the System Controllers connect to System Controller #1 in a Daisy-Chain type of connection. Refer to the connections
and controller settings shown below.
4
Termination and Controller Unit Number Setting
Controller 1
Controller 2
Controller 3
Controller 4
Matrix Switcher WJ-SX550A
Control Board
CONTROL
DATA 1
DATA 2
DATA 3
DATA 4
DATA 5
DATA 6
DATA 7
DATA 8
TEST 1
TEST 2
Note: Any data port can be used.
Termination
Controller
Switch
Unit Number
OFF
1
OFF
2
OFF
3
ON
4
DATA
IN
OUT
DATA
IN
OUT
DATA
IN
OUT
DATA
IN
OUT
Notes:
• Do not connect more than 4 System Controllers in a
daisy-chain connection as unstable operation of the
system might occur.
• In the above connection, the operations may be acti-
vated with poor response.
It is recommended to connect the System Controllers
in a Home Run type of connection if operating the
plural controllers at the same time.
Daisy-Chain Connections
Note: Do not use the "0" or "9" controller unit num-
bers.
-58-
CONTROLLER
UNIT NO.
1-8
Controller 1
TERM
0
ON
OFF
5
CONTROLLER
UNIT NO.
1-8
Controller 2
TERM
0
ON
OFF
5
CONTROLLER
UNIT NO.
1-8
Controller 3
TERM
0
ON
OFF
5
CONTROLLER
UNIT NO.
1-8
Controller 4
TERM
0
ON
OFF
5