Fujitsu PRIMERGY RX200 S2 User Manual page 225

Hide thumbs Also See for PRIMERGY RX200 S2:
Table of Contents

Advertisement

Item
Mode
Timeout Value
ASR&R Boot Delay (min)
Power Cycle Delay
5 (Fixed parameter)
Boot Retry Counter
Diagnostic System
Disabled (Fixed
parameter)
Critical Temperature
Disabled (Fixed
Monitoring
parameter)
Memory scrub
Enabled (Fixed parameter)
BIOS runtime logging
Enabled (Fixed parameter)
Clear Screen Delay (sec)
IPMI
[Enter]
CPU Status
[Enter]
Memory Status
[Enter]
LAN Setting
[Enter]
Console Redirection
[Enter]
table: Items on the Server Menu
Setting
• Continue (at the time of
Sets the operation to be performed when a timeout
purchase)
occurs during OS boot monitoring.
• Reset
• Continue: The boot sequence is continued.
• Power Cycle
• Reset: The server restarts automatically and starts
• Power Cycle: The server turns off automatically.
• 0 (at the time of
When [O/S Boot Timeout] is set to [Enabled], the
purchase)
system restarts automatically if the OS fails to start
• 1-100
up within the time set for this item.
• 2 (at the time of
Sets the standby time for startup after shutdown due
purchase)
to trouble (such as overheating) in minutes. The
• 1-30
system restarts after the set standby time.
Sets the time until the server is turned on after it is
turned off.
• 3 (at the time of
Sets the maximum number of OS startup retries.
purchase)
• 0-7
Sets the operation to be performed when the number
of system boot retries exceeds the number specified
in [Boot Retry Counter].
Sets whether or not to turn the power off in the event
of abnormal temperature.
Sets whether or not the BIOS detects and corrects
memory errors.
Sets whether or not the CPU, memory, or PCI slot
errors are recorded in the error log.
• 5 (at the time of
Sets the time (seconds) to display the last BIOS
purchase)
message screen before the OS starts up.
• 0-31
Configures the Baseboard Management Controller
(BMC).
Displays whether or not to allow the use of the
installed CPU.
Sets whether or not to allow the use of the installed
memory.
Sets the LAN for remote operations with Remote
Control Service.
Configures detailed settings for console redirection.
PRIMERGY RX200 S2 User's Guide
Description
POST.
The server turns on automatically after the time
specified in [Power cycle Delay].
"8.2.12 IPMI Submenu" (pg.226)
"8.2.13 CPU Status Submenu" (pg.227)
"8.2.14 Memory Status Submenu" (pg.228)
"8.2.15 LAN Setting Submenu" (pg.229)
"8.2.16 Console Redirection Submenu" (pg.230)
8
225