How To Install An Internal Hard Disk Unit - Fujitsu PRIMERGY RX200 S2 User Manual

Hide thumbs Also See for PRIMERGY RX200 S2:
Table of Contents

Advertisement

■ Connections
The figure below shows the connection of internal hard disk units.
Bay1
Bay2
SCSI ID: 1
SCSI ID: 0

7.7.3 How to Install an Internal Hard Disk Unit

This section explains how to install an internal hard disk unit.
1
Open the rack door.
"1.4.1 Opening the Rack Door" (pg.28)
2
Turn off the server and peripheral devices, then unplug the power cables from
the server.
"1.4.3 Turning Off the Server" (pg.32)
3
Touch a metal part of the server to discharge static electricity.
4
Remove the dummy unit from the bay to accommodate an internal hard disk
unit.
A dummy unit is inserted into a bay not occupied by an internal hard disk unit. Pull the dummy
unit out towards you with the latches on both sides pressed inward.
Be sure to keep the removed dummy units for later use.
[Rear]
Latches
PRIMERGY RX200 S2 User's Guide
SCSI cable: Standard
Onboard SCSI connector
Baseboard
7
193

Advertisement

Table of Contents
loading

Table of Contents