7 SAFE STOPPING DISTANCE
RH-3CRH
Stopping time and stopping distance (emergency stop)
Axis
Arm extension
L=100%
J1
L=66%
L=33%
J2
-
J3
-
J4
-
Stopping time and stopping distance (power off)
Axis
Arm extension
J1
L=100%
J2
-
J3
-
J4
-
7-122 Maximum Stopping Time and Maximum Operating Angle
Load rate
Ovrd 33%
M=100%
0.45
M=66%
0.46
M=33%
0.44
M=0%
0.41
M=100%
0.39
M=66%
0.41
M=33%
0.39
M=0%
0.46
M=100%
0.35
M=66%
0.38
M=33%
0.36
M=0%
0.44
M=100%
0.41
M=66%
0.43
M=33%
0.41
M=0%
0.39
M=100%
0.44
M=66%
0.43
M=33%
0.41
M=0%
0.39
Load 2
0.60
Load 1
0.47
Stopping time [s]
Load rate
Ovrd 100%
M=100%
M=100%
M=100%
Load 2
Stopping time [s]
Ovrd 66%
Ovrd 100%
0.61
0.78
0.66
0.87
0.63
0.84
0.61
0.81
0.55
0.72
0.61
0.82
0.59
0.80
0.66
0.86
0.52
0.69
0.58
0.78
0.56
0.77
0.64
0.84
0.58
0.75
0.63
0.83
0.61
0.81
0.59
0.79
0.64
0.84
0.62
0.83
0.61
0.81
0.59
0.79
0.67
0.74
0.60
0.74
Stopping distance
J1/J2/J4 axis [deg]
J3 axis [mm]
Ovrd 100%
0.61
0.57
0.27
0.63
Stopping distance
J1/J2/J4 axis [deg]
J3 axis [mm]
Ovrd 33%
Ovrd 66%
46.48
125.62
57.88
162.80
54.69
156.43
51.78
150.61
40.94
114.55
51.94
150.92
49.54
146.13
57.51
162.07
37.18
107.04
47.97
142.98
46.17
139.38
54.81
156.67
43.45
119.58
54.25
155.55
51.51
150.07
49.17
145.38
85.96
245.11
83.14
239.46
79.92
233.03
76.48
226.14
95.80
212.86
143.95
364.97
170.70
174.28
168.38
208.89
Ovrd 100%
241.34
320.10
310.46
301.64
224.57
302.11
294.84
319.00
213.18
290.08
284.62
310.82
232.18
309.12
300.82
293.71
485.61
477.05
467.31
456.88
355.68
673.29

Advertisement

Table of Contents
loading

Table of Contents