Caring for the Lithium-Ion Battery (continued)
Year
1
2
3
4
Note:
Your results may vary depending on the distance you need to transport the machine,
the contact setting of the bedknife, and other factors as discussed in this section.
To achieve maximum life and use from your battery, apply the following care guidelines:
• Do not open the battery pack. There are no user serviceable parts inside. If you open the
pack you will void your warranty. The pack is protected by tamper-alerting devices.
• Store/park the machine in a clean, dry garage or storage area, away from direct
sunlight and heat sources. Do not store it in a location where the temperature drops
below -30°C (-22°F) or rises above 60°C (140°F). Temperatures outside of this range
will damage your battery. High temperatures during storage, especially at a high state
of charge, reduces the life of the batteries.
• When storing for more than 10 days, ensure that the machine is in a cool location, out of
sunlight, and at least 50% charged.
• If you are mowing in hot conditions or in sunlight, the battery may overheat. If this
happens, a high-temperature alert will appear on the InfoCenter. In this condition, the
machine no longer operates with the reel engaged and the machine slows down.
Immediately drive the machine to a cool location out of the sun, turn off the machine, and
allow the battery to cool fully before resuming operation.
• Keep the battery pack cover clean. The white color reflects sunlight and slows the heat
buildup in the battery pack. A dirty cover increases the heat in the battery pack each day
and reduces the energy capacity.
• Adjust the bedknife to reel contact to be as light as possible. This reduces the power
needed to run the reel and increases the amount of work the machine performs on each
charge.
3460-892A
Area Cut Per Full Charge
3,809 m
2
(41,000 ft
3,623 m
2
(39,000 ft
3,252 m
2
(35,000 ft
3,066 m
2
(33,000 ft
Page 5–11
2
)
2
)
2
)
2
)
Operation: Battery Operation