Mitsubishi Electric FR-A720-00030-NA Instruction Manual page 93

Table of Contents

Advertisement

Parameter List
Func-
Parameter
tion
Cumulative power monitor digit shifted
891
times
892
Load factor
Energy saving monitor reference
893
(motor capacity)
Control selection during commercial
894
power-supply operation
895
Power saving rate reference value
896
Power unit cost
897
Power saving monitor average time
898
Power saving cumulative monitor clear 0, 1, 10, 9999
899
Operation time rate (estimated value)
C0
FM terminal calibration
(900)
*6
C1
AM terminal calibration
(901)
*6
C2
Terminal 2 frequency setting bias
(902)
frequency
*6
C3
Terminal 2 frequency setting bias
(902)
*6
125
Terminal 2 frequency setting gain
(903)
frequency
*6
C4
Terminal 2 frequency setting gain
(903)
*6
C5
Terminal 4 frequency setting bias
(904)
frequency
*6
C6
Terminal 4 frequency setting bias
(904)
*6
126
Terminal 4 frequency setting gain
(905)
frequency
*6
C7
Terminal 4 frequency setting gain
(905)
*6
C12
Terminal 1 bias frequency (speed)
(917)
*6
C13
Terminal 1 bias (speed)
(917)
*6
C14
Terminal 1 gain frequency (speed)
(918)
*6
C15
Terminal 1 gain (speed)
(918)
*6
C16
Terminal 1 bias command (torque/
(919)
magnetic flux)
*6
C17
Terminal 1 bias (torque/magnetic flux)
(919)
*6
C18
Terminal 1 gain command (torque/
(920)
magnetic flux)
*6
C19
Terminal 1 gain (torque/magnetic flux)
(920)
*6
C38
Terminal 4 bias command (torque/
(932)
magnetic flux)
*6
C39
Terminal 4 bias (torque/magnetic flux)
(932)
*6
C40
Terminal 4 gain command (torque/
(933)
magnetic flux)
*6
C41
Terminal 4 gain (torque/magnetic flux)
(933)
*6
989
Parameter copy alarm release
990
PU buzzer control
991
PU contrast adjustment
82
Name
0 to 4, 9999
30 to 150%
0.1 to 55/0 to 3600kW
0, 1, 2, 3
0, 1, 9999
0 to 500, 9999
0, 1 to 1000h, 9999
0 to 100%, 9999
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400%
0 to 300%
0 to 400%
0 to 300%
0 to 400%
0 to 300%
0 to 400%
0 to 300%
10/100
0, 1
0 to 63
Minimum
Setting Range
Setting
Increments
1
0.1%
0.01/
*2
0.1kW
1
1
0.01
1h
1
0.1%
0.01Hz
0.1%
0.01Hz
0.1%
0.01Hz
0.1%
0.01Hz
0.1%
0.01Hz
0.1%
0.01Hz
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
1
1
1
Refer
Initial Value
to
Page
9999
283
100%
283
Inverter
rated
283
*2
capacity
0
283
9999
283
9999
283
9999
283
9999
283
9999
283
267
267
0Hz
299
0%
299
Hz
299
60
100%
299
0Hz
299
20%
299
Hz
299
60
100%
299
0Hz
299
0%
299
Hz
299
60
100%
299
0%
305
0%
305
150%
305
100%
305
0%
305
20%
305
150%
305
100%
305
10/100
405
*2
1
403
58
403
Customer
Setting

Advertisement

Table of Contents
loading

Table of Contents