Mitsubishi Electric FR-A720-00030-NA Instruction Manual page 361

Table of Contents

Advertisement

Communication operation and setting
No.
Item
Parameter clear
8
All clear
9
Parameters
10
Link parameter
11
extended setting
Second
parameter
12
changing
(instruction code
HFF=1, 9)
Refer to page 343 for data formats (A, A', B, B', C, D)
REMARKS
 Set 65520 (HFFF0) as a parameter value "8888" and 65535 (HFFFF) as "9999".
 For the instruction codes HFF, HEC and HF3, their values are held once written but cleared to zero when an inverter reset or all
clear is performed.
Example) When reading the C3 (Pr. 902) and C6 (Pr. 904) settings from the inverter of station 0
Computer Send Data
1)
ENQ 00 FF 0 01 82
2)
ENQ 00 EC 0 01 7E
3)
ENQ 00 5E 0 0F
4)
ENQ 00 60 0 FB
To read/write C3 (Pr. 902) and C6 (Pr. 904) after inverter reset or parameter clear, execute from 1) again.
350
Read/
Instruction
Write
Code
All parameters return to the initial values.
Whether to clear communication parameters or not can be
selected according to data. ( : Clear, : Not clear)
Refer to page 472 for parameter clear, all clear, and communication
parameters.
All parameter clear
Write
HFC
When clear is executed for H9696 or H9966, communication-related
parameter settings also return to the initial values. When resuming
operation, set the parameters again. (Turning OFF the power supply
while clearing parameters with H5A5A or H55AA sets back the
communication parameter settings to the initial settings.)
Executing clear will clear the instruction code HEC, HF3, and HFF
settings.
In the password locked status (refer to page 318), only H9966 and
H55AA (all parameter clear) are valid.
H00 to
Refer to the instruction code (Refer to page 472) and write and/or
Read
H63
read the values as required.
When setting Pr. 100 and later, link parameter extended setting must
H80 to
Write
be set.
HE3
Parameter description is changed according to the H00 to H09
Read
H7F
setting.
For details of the setting, refer to the instruction code (Refer to page
Write
HFF
472).
When setting the calibration parameters
H00:Frequency
Read
H6C
H01: Parameter-set analog value
H02: Analog value input from terminal
1
Refer to the list of calibration parameters on the next page for calibration
*
parameters.
Write
HEC
2
The gain frequency can also be written using Pr. 125 (instruction code
*
H99) or Pr. 126 (instruction code H9A).
Inverter Send Data
ACK 00
ACK 00
STX 00 0000 ETX 25
STX 00 0000 ETX 25
Data Description
Clear Type
Data
H9696
Parameter clear
H5A5A
H9966
H55AA
*2
Description
Set "H01" in the extended link parameter.
Set "H01" in second parameter changing.
C3 (Pr. 902) is read. 0% is read.
C6 (Pr. 904) is read. 0% is read.
Communication Pr.
*1
Number of
Data Digits
(format)
4 digits
(A,C/D)
4 digits
(B.E/D)
4 digits
(A,C/D)
2digits
(B.E'/D)
2digits
(A',C/D)
2digits
(B.E'/D)
2digits
(A',C/D)

Advertisement