Selection and protection of a motor
 To enter the Pr. 92 and Pr. 93 motor constants in [mH]
<Operating procedure>
1) Set Pr. 71 according to the motor used.
Mitsubishi standard
motor
Mitsubishi high
efficiency motor
Mitsubishi constant-
torque motor
Vector control
dedicated motor
*1 For other settings of Pr. 71 , refer to page 189 .
2) In the parameter setting mode, read the following parameters and set desired values.
Calculate the Pr. 94 value from the following formula.
Pr. 94 setting = (1 -
R1
I1
V
M
L1= I1+ M: Primary inductance
L2= I2+ M: Secondary inductance
Motor equivalent circuit diagram
Parameter
Number
Motor excitation current
82
(no load current)
90
Motor constant (R1)
91
Motor constant (R2)
92
Motor constant (L1)
93
Motor constant (L2)
94
Motor constant (X)
859
Torque current
3)Refer to the following table and set Pr. 83 and Pr. 84 .
Parameter
Number
83
Rated motor voltage
84
Rated motor frequency
* The initial value differs according to the voltage level. (200V/400V)
REMARKS
· When "9999" is set in Pr. 82, Pr. 90 to Pr. 94, Pr. 859, Mitsubishi motor (SF-JR, SF-HR,SF-JRCA, SF-HRCA, SF-V5RU
(1500r/min series), etc.) constants are used.
200
Motor
SF-JR
SF-JR 4P 1.5kW or less
SF-HR
SF-JRCA 4P
SF-TH (constant torque)
SF-HRCA
SF-V5RU (1500r/min series)
SF-V5RU (except for 1500r/min series)
2
M

)
100 (%)
L1
L2
I2
R1: Primary resistance
R2: Secondary resistance
I1: Primary leakage inductance
R2/S
I2: Secondary leakage inductance
M: Excitation inductance
S: Slip
Name
02150 (01100) or less
02880 (01440) or more
02150 (01100) or less
02880 (01440) or more
02150 (01100) or less
02880 (01440) or more
02150 (01100) or less
02880 (01440) or more
02150 (01100) or less
02880 (01440) or more
02150 (01100) or less
02880 (01440) or more
02150 (01100) or less
02880 (01440) or more
Name
Setting Range
Pr.71 Setting
0
20
40
1
50
30
14
Setting Range
200V class (400V class)
0 to 500A, 9999
0 to 3600A, 9999
0 to 50, 9999
0 to 400m, 9999
0 to 50, 9999
0 to 400m, 9999
0 to 1000mH, 9999
0 to 400mH, 9999
0 to 1000mH, 9999
0 to 400mH, 9999
0 to 100%, 9999
0 to 100, 9999
0 to 500A, 9999
0 to 3600A, 9999
0 to 1000V
10 to 120Hz
*1
Setting
Increments
0.01A
0.1A
0.001
0.01m
0.001
0.01m
0.1mH
0.01mH
0.1mH
0.01mH
0.1%
0.01%
0.01A
0.1A
Setting
Initial
Increments
Value
0.1V
200V/400V
0.01Hz
60Hz
Initial
Value
9999
9999
9999
9999
9999
9999
9999