Parameter
Name
Number
450
Second applied motor
453
Second motor capacity
Number of second
454
motor poles
Second motor
455
excitation current
Rated second motor
456
voltage
Rated second motor
457
frequency
Second motor
458
constant (R1)
Second motor
459
constant (R2)
Second motor
460
constant (L1)
Second motor
461
constant (L2)
Second motor
462
constant (X)
Second motor auto
463
tuning setting/status
Tuning data unit
684
switchover
859
Torque current
Initial
Setting Range
Value
200V class (400V class)
0 to 8, 13 to 18, 20,
23, 24, 30, 33, 34, 40, 43, 44,
9999
50, 53, 54
9999
02150 (01100) or
less
9999
02880 (01440) or
more
9999
2, 4, 6, 8, 10
9999
9999
02150 (01100) or
less
02880 (01440) or
9999
more
9999
200/400V
0 to 1000V
*
60Hz
10 to 120Hz
02150 (01100) or
0 to 509999
less
9999
02880 (01440) or
more
02150 (01100) or
0 to 509999
less
9999
02880 (01440) or
more
02150 (01100) or
(0 to 1000mH)
less
9999
0 to 3600m
02880 (01440) or
(0 to 400mH)
more
02150 (01100) or
(0 to 1000mH)
less
9999
0 to 3600m
02880 (01440) or
(0 to 400mH)
more
02150 (01100) or
less
9999
02880 (01440) or
more
0
1
0
101
0
0
1
02150 (01100) or
less
02880 (01440) or
9999
more
9999
Selection and protection of a motor
Set when using the second motor.
(same specifications as Pr. 71)
Not function
0.4 to 55kW
Set the capacity of the second motor.
0 to 3600kW
V/F control
Set the number of poles of the second motor.
V/F control
0 to 500A
Tuning data of the second motor
(The value measured by offline auto
tuning is automatically set.)
0 to 3600A
Use the Mitsubishi motor (SF-JR, SF-HR,
SF-JRCA, SF-HRCA, SF-V5RU (1500r/
min series), etc.) constants
Set the rated voltage (V) of the second
motor.
* The initial value differs according to the
voltage level. (200V/400V)
Set the rated motor frequency (Hz) of the
second motor.
0 to 400m
9999
0 to 400m
9999
0 to 50
9999
Tuning data of the second motor
(The value measured by offline auto
tuning is automatically set.)
9999: Use the Mitsubishi motor (SF-JR,
9999
SF-HR, SF-JRCA, SF-HRCA, SF-V5RU
0 to 50
(1500r/min series), etc.) constants
9999
9999
0 to 500
(0 to 100%)
9999
0 to 100
(0 to 100%)
9999
Second motor auto tuning is not performed
Offline auto tuning is performed without
second motor running
Offline auto tuning is performed with
second motor running
Internal data converted value
Displayed in "A, , mH, %"
0 to 500A
Tuning data
(The value measured by offline auto
tuning is automatically set.)
0 to 3600A
Use the Mitsubishi motor (SF-JR, SF-HR,
SF-JRCA, SF-HRCA, SF-V5RU (1500r/
min series), etc.) constants
Description