Mitsubishi Electric FR-A720-00030-NA Instruction Manual page 82

Table of Contents

Advertisement

Func-
Parameter
tion
80
Motor capacity
81
Number of motor poles
82
Motor excitation current
83
Rated motor voltage
84
Rated motor frequency
89
Speed control gain (magnetic flux vector)
90
Motor constant (R1)
91
Motor constant (R2)
92
Motor constant (L1)
93
Motor constant (L2)
94
Motor constant (X)
95
Online auto tuning selection
96
Auto tuning setting/status
100
V/F1(first frequency)
101
V/F1(first frequency voltage)
102
V/F2(second frequency)
103
V/F2(second frequency voltage)
104
V/F3(third frequency)
105
V/F3(third frequency voltage)
106
V/F4(fourth frequency)
107
V/F4(fourth frequency voltage)
108
V/F5(fifth frequency)
109
V/F5(fifth frequency voltage)
110
Third acceleration/deceleration time
111
Third deceleration time
112
Third torque boost
113
Third V/F (base frequency)
114
Third stall prevention operation current 0 to 220%
Third stall prevention operation
115
frequency
116
Third output frequency detection
117
PU communication station number
118
PU communication speed
119
PU communication stop bit length
120
PU communication parity check
121
Number of PU communication retries
122
PU communication check time interval
123
PU communication waiting time setting 0 to 150ms, 9999
124
PU communication CR/LF selection
Terminal 2 frequency setting gain
125
frequency
Terminal 4 frequency setting gain
126
frequency
Name
Setting Range
0.4 to 55kW, 9999/
0 to 3600kW, 9999
2, 4, 6, 8, 10, 12, 14, 16,
18, 20, 9999
0 to 500A, 9999/
0 to 3600A, 9999
0 to 1000V
10 to 120Hz
0 to 200%, 9999
0 to 50
0 to 400m, 9999
0 to 50
0 to 400m, 9999
0 to 50
0 to 3600m (0 to 400mH), 9999
0 to 50
0 to 3600m (0 to 400mH), 9999
0 to 500
0 to 100 (0 to 100%), 9999
0 to 2
0, 1, 101
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 3600/360s, 9999
0 to 3600/360s, 9999
0 to 30%, 9999
0 to 400Hz, 9999
0 to 400Hz
0 to 400Hz
0 to 31
48, 96, 192, 384
0, 1, 10, 11
0, 1, 2
0 to10, 9999
0, 0.1 to 999.8s, 9999
0, 1, 2
0 to 400Hz
0 to 400Hz
Minimum
Setting
Increments
0.01/0.1kW
*2
*2
1
0.01/0.1A
*2
*2
0.1V
0.01Hz
0.1%
0.001/
, 9999/
0.01m
*2
*2
0.001/
, 9999/
0.01m
*2
*2
0.001(0.1mH)/
(0 to 1000mH), 9999/
0.01m(0.01mH)
*2
*2
0.001(0.1mH)/
(0 to 1000mH), 9999/
0.01m(0.01mH)
*2
*2
0.01 (0.1%)/
(0 to 100%), 9999/
0.01 (0.01%)
*2
*2
1
1
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.1/0.01s
0.1/0.01s
0.1%
0.01Hz
0.1%
0.01Hz
0.01Hz
1
1
1
1
1
0.1s
1
1
0.01Hz
0.01Hz
Parameter List
Refer
Customer
Initial Value
to
Setting
Page
147,
9999
192
147,
9999
192
9999
192
200/400V
192
*7
Hz
192
60
9999
147
9999
192
9999
192
9999
192
9999
192
9999
192
0
202
0
192
9999
167
0V
167
9999
167
0V
167
9999
167
0V
167
9999
167
0V
167
9999
167
0V
167
9999
175
9999
175
9999
145
9999
161
150%
152
0
152
60
Hz
250
0
340
192
340
1
340
2
340
1
340
9999
340
9999
340
1
340
Hz
299
60
Hz
299
60
71
4

Advertisement

Table of Contents
loading