Advertisement

4.3 Tension / torque setting

Similarly to description given on page 31, [ 張力 / トルク ] key is acceptable from any screen condition on the
screen displayed prior to power failure after turning on the power source.
A D J U S T
張力
トルク
S E T *
D I A M N T
T A P M N T
S P
* * * %
V R
* * * %
Set display [
]
to line of [ SET ]
Set display [
]
to line of [ ADJUST ]
Reset setting mode
セ ッ テ イ
S E T T N G
< ADJUST (adjustment) >
The cursor key after pressing the [ 設定 ] key functions to increase / decrease the numeric.
The numeric is increased / decreased each time when the [INC ] key or [DEC ] key is pressed.
If such key is pressed continuously, the numeric is incerased / decerased at high speed.
Such numeric increase / decrease is valid even if the [ 実行 ] key is not presse.
When necessary to reset hte setting mode, press the [ 実行 ] key or [ クリア ] key.
When the numeric is input, such input numeric is validated when the [ 実行 ] key is pressed.
If the numeric other than 0 ~ 100% is input, however, it is not accepted, but error message is displayed.
In such a case, press the [ クリア ] key and input the correct numeric.
The value adjusted can be also displayed by bar graph.
When the SET is set to "0", the ADJUST displays "0%" and the setting will not be changed.
If any power failure occurs, the value of ADJUST is saved from RAM to EEPROM memory.
< MNT (monitor) >
DIA MNT displays the result of winding diameter calculated, while TAP MNT displays the current taper
ratio.
SP is used to monitor the input voltage ( 8V = 100% ), using the external variable resistor, while VR to
monitor the adjustment value ( V = 100% ) using the built-in variable resistor. 0% is displayed for invalid
side.
TRQ displays the current output with full-scale at 100%.
When the non-linearity compensation is executing, it is output as torque conversion value.
When the [ 張力 / トルク ] key is pressed, and then the [DEC ] key two times, the screen is changed to
DIA MNT, TAP MNT screen. When the [DEC ] key is further pressed, the screen is changed to SP, VR,
TRQ screen.
* * *
bar graph
* * * *
m m φ
* * *
T R Q
* * * %
or
設定
実行
Correction
設定
Numeric value
increment / decrement
クリア
Correction
エ ラ -
E R R O R
---------- SET=1
When the [ 張力 / トルク ] key is pressed, the
screen as shown at left is displayed, in which
the line or screen changeover is executable,
using cursor keys ( , ).
The screen without "
monitor screen.
When it is set to "0", the built-in variable resis-
tor is invalidated ( external variable resistor is
validated ), and when it is set to "1", the built-
in variable resistor is validated ( external vari-
able resistor is invalidated ).
実行
Error
33
" mark indicates the