Supplementary Description - Mitsubishi Electric LE-50PAU Instruction Manual

Power amplifier/tension controller
Table of Contents

Advertisement

6. Supplementary description

< 1 to 5V input and 4 to 20mA input of power amplifire >
When the power amplifire is operated under " 0 to 5V input mode " (DIP SW1 to SW3= ON), it is possible
to change the mode to "1 to 5V input mode " by performing the following operation.
When using the power amplifire under " 4 to 20 mA mode ", connect a precision resistor ( 250Ω, 1W )
across the terminals SP and SN, and use it as " 1 to 5V input mode".
Power ON
INC
Change of
numeric value
< 1 to 5V input and 4 to 20mA input of power amplifire >
It is possible to change the terminals S1-S2 ( aux. power output ) of the LE-50PAU from the aux. power
output mode to the [ RUN ] output mode by performing the following operations.
[ RUN ] output means that 12VDC ( load current : 100mA or less ) is output while the LE-50PAU is op-
erating properly.
When any wire deiconnection or short-curcuit occurs in the cluctch / brake for one second or over, which
is connected across the terminals PP and PN, the output is turned off ( 0V ).
When the terminals S1-S2 are used under [ RUN ] output mode, the remote input SC of aux. power
source is invalidaded, and the timer setting value ( SST ) of aux. power source is also invalidated.
Power ON
INC
Change of
numeric value
< 1 to 5V input and 4 to 20mA input of power amplifire >
ST input, RS input and AUTO mode / MANUAL mode
Manual operation mode
• Outpur correspondeng to SP input
ST input = ON
Last condition is retained for calcula-
tion of winding diameter.
Automatic operation mode
ST input = ON
Output of calculated initial diameter
Stop of winding diameter calculation
Output
display
DEC
Press the [ MODE ] key with
[DEC ] key pressed.
DEC
1 to 5V input mode
Output
display
DEC
Press the [ INC
[DEC ] key pressed.
DEC
RUN output moed
RS input = ON
( Initial diameter reset )
38
MODE
Display of current status
0 ~ 5V input mode
SET
DEC
Reset setting mode
MODE
INC
Display of current status
] key with
Aux.power output mode
SET
DEC
Reset setting mode
MODE
RS input = OFF
Automatic operation mode ( START )
Calculation output of winding diameter
Calculation of winding daimeter
Automatic operation mode ( STOP )
Last condition is retained for calculation
output of winding diameter.
Stop of winding diameter calculation
MODE
INC