4.3 Connection of input circuit

1. Analog input
(1) External variable resistor
• To input the signal, using the external variable resistor, connect it as shown below in the following
drawing, turn on the DIP switch SW2 and turn off the SW3 ( input : 0 to 8V ).
• Use a variable resistor of 2kΩ ( linear characteristic ).
(2) LE-30CTN, LE-40MTA, LE-40MTB, LD-FX
• Connect the LE-50PAU power amplifire to the LE-30CTN, LE-40MTA, LE-40MTB or LD-FX ten-
sion controller as shown below in the following drawing, turn on the DIP switch SW2 and SW3,
and set the input to 0 to 5V.
2. Digital input
• Use a switch for small signal suitable to small current (12VDC 5mA ).
• When the power amplifire output is not turned ON / OFF remotely, keep across [RC] - [SN] short-cir-
cuited.
• When the stop gain, bias or aux.power amplifire is not used, keep the [ST] terminal short-circuited and
the [SC] terminal opened.
------ For 1 to 5V input and 4 to 20mA input, refer to page 48.
2kΩ
0~8V
External
variable resistor
Grounding resistance
100Ω or less
LE-30CTN
LE-40MTA
LE-40MTB
LD-FX
Control signal for
servo amplifier
power amplifier
Start (start/stop)*
Power amplifire output ON
Aux.power output ON
SET
DC 8V
SP
SN
LE-50PAU
SG
DIP SW.1=ON
(Unused)
SET
0~5V
SP
SN
SG
Class D grounding
( 100Ω or less )
ST
RC
SC
SN
13
DC 8V
LE-50PAU
DIP SW.1=ON
LE-50PAU
2.2kΩ
12V
DIP SW.1=ON