3. Operator panel

3.1 Introduction / Set item list

最 小
最 大
初 期
• The last screen display appears when the power supply is turned on again by memorize the display
screen befor blacking out.
< Set item list >
Set item
Minimum diameter D1
Small diameter D2
Large diameter D3
Maximum diameter D4
Speed
SPD
Adjustment
variable resistor
Stop gain
Stop timer
Input level
10% torque
40% torque
These set data is memorized in the EEPROM memory in the LE-50PAU power amplifire.
*1 The set input signal level 8V is assumed 100%.
*2 The output ins assumed 100% befor stopping.
*3 If the transmission torque at the rated current is assumed 100%, it is a transmission torque at the cur-
rent of 10%, 20%, 40%, 80% of the rated current.
*4 If the tension of an initial diameter ( it is maximum diameter in the unwinding and minimum diameter
in the winding ) is assumed 100%, it is one that the tension in present diameter was expressed by the
percentage.
*5 The torque when the rated current enegizes ( full scale output ) is assumed 100%.
速 度
張 力
クリア
厚 さ
トルク
エラー
FNC
設 定
FNC
FNC
モニタ
予 備
最 終
実 行
Initial
Set range
value
1~ 1,999mm
1~ 1,999mm
1~ 1,999mm
1~ 1,999mm
1~ 999m/min
0 ~ 100% *1
0%
0 ~ 300% *2
100%
0 ~ 30 sec
10 sec
0.5 ~ 8.0V
1.0 ~ 99.0% *3
10%
1.0 ~ 99.0% *3
40%
• The LE-5AP operator panel is installed in the panel
surface of the control console.
• The LE-5AP operator panel has LCD with LED back
light of 16 character two line. Various setting and
monitors are done with 25 keys.
• The key which the operator operates at actual opera-
tion is (最小), (最大), (速度/厚さ), (張力/トルク), (ク
リア / エラー ).
• The FNC1 ~ FNC3 keys are used to set the initial set-
ting.
• The (初期), (予備), (最終) keys are not used. 0 ~ 9 and
other keys are shown in item 4 or item 5.
Set item
0
Minimum dia. Tension T1
0
Small dia. Tension T2
0
Large dia. Tension T3
0
Maximum dia. Tension T4
0
Thickness
THK
Variable resisor
validity / invalidity
Stop bias
Aux. Timer
Winding maximum
5V
taper ratio
20% torque
80% torque
29
Set range
Initial value
20 ~ 500% *4
100%
20 ~ 500% *4
0%
20 ~ 500% *4
0
20 ~ 500% *4
100%
0.1 ~ 3,276.7µm
0
0
1 or 0
( invalidity )
0 ~ 60% *5
0%
0 ~ 30 sec
10 sec
20 ~ 500%
100%
1.0 ~ 99.0% *3
20%
1.0 ~ 99.0% *3
80%

Advertisement