Common technical data
Overvoltage category
pollution degreee
Power supply
Rated operation voltage Ue
Rared insulation voltage Ui
Rated impulse withstand voltage Uimp
Output contacts
Contact rated voltage with reinforced insulation between different contacts
Terminals
11, 12, 13
21, 22, 23
31, 32, 34
43, 44
53, 54
63, 64
73, 74
Environmental specifications
Permissible ambient temperature in operation
Permissible ambient temperature in transportation
and storage
Humidity
Altitude
Degree of protection
Safety parameters for application according to IEC61508
Life time
PFD
III
3
100 -250 V DC
100-240 V AC 50-60 HZ
250 V with reinforced insulation
4 kV
Description
Ui
IRF signal
250 V
Signal relay
250 V
Signal relay
250 V
Trip contact
250 V
Trip contact
250 V
Trip contact
250 V
50 V
50 V DC
- 25 to + 55 °C
- 25 to + 70°C
Maximum 95%
2000 meter above sea level
IP20 Arc Monitor
IP54 HMI front side
10 years
-03
3.49 x 10
Technical data
Ue
250 V AC 50-60 HZ, 250 V DC
250 V AC 50-60 HZ, 250 V DC
250 V AC 50-60 HZ, 250 V DC
250 V AC 50-60 HZ, 250 V DC
250 V AC 50-60 HZ, 250 V DC
250 V AC 50-60 HZ, 250 V DC
0.5 kV
Uimp
4 kV
4 kV
4 kV
4 kV
4 kV
4 kV