LAN Interface – Rightmost field
Indicates the speed and duplex mode for this Ethernet port
The possible readings are:
10M HDX
10M FDX
100M HDX
100M FDX
1000M HDX*
1000M FDX*
* Applicable to ports G1 and G2 only.
Also see the Rate-Allow and Rate-In Use fields in the Port Details tab.
Monitor Port
For test purposes, one port can be set as a monitor port. The selection
of local ports that will be feeding their ingress (IN) and/or egress (OUT)
traffic to the Monitor port is made in the Monitored Traffic column.
Note: For proper operation, the monitor and monitored ports must
have compatible Port Type settings and they must belong to the same
D-PVLAN.
Monitored Traffic
Possible selections are:
-
IN
OUT
IN+OUT
Note: This field is grayed out and disabled for monitor ports. The
whole column is grayed out and disabled if none of the ports is set as a
monitor port.
Caveat: Any egressing local-to-local unicast frame whose DA is known
(i.e. present in the "LAN" MAC address table) will not be mirrored until
at least one frame from the DA‟s owner is received.
Copy Port 1 Config to ports 2-6, G1, G2
Copies all configuration settings made for Port #1 to Ports #2 to #6 and
to ports G1 and G2.
Note: This action cannot be undone.
Copyright  GE Multilin Inc. 2010-2012
10 Mb/s, Half Duplex
10 Mb/s, Full Duplex
100 Mb/s, Half Duplex
100 Mb/s, Full Duplex
1000 Mb/s, Full Duplex*
1000 Mb/s, Full Duplex*
This port is not mirroring traffic (default).
This port‟s ingress traffic is mirrored to the monitor port.
This port‟s egress traffic is mirrored to the monitor port.
This port‟s ingress and egress traffic is mirrored to the
monitor port.
342-86400-498PS
Issue 1.2
April 2012
Page 89