correct K Value.
Off_s: Review your flow sensor's documentation for its
correct Offset value.
PPG (if Bermad selected): Pulse per gallon based on flow
meter wiring. See your Bermad flow meter documentation
for proper setting.
Rain Bucket Configuration
Input : 3
Tip
: 0.01 in
Max
: 01.00 in
Unit
: English (in)
Alarm : On
R_win : 24hr
Act
: Rain Hold
Hold
: 02days
Count : 4
Hr: 02 H_Cnt:00001
Tip: The amount of water per tip. The typical rain bucket
might have a tip point of 0.01". Check your rain bucket's
documentation for correct tip point.
Max: This is the limit at which the alarm will trip. If the
Tip unit is 0.01 inch, and the Max limit is 1 inch, it would
take 100 tips (within the R_win window) to trigger the
alarm.
Unit: Select either English or Metric for display of rain
bucket data in either inches or millimeters.
Alarm: On or Off. Turn on the alarm
R_win: Set the period of time (as a moving window)
that the controller will calculate rain bucket tips towards
reaching the max limit.
Act: If an alarm is triggered, this is the Action that the
controller will take. Possible choices are:
None. The alarm will only alert the operator.
Start Station. Starts a specified station.
Cancel Station. Cancels a specified station.
Cancel All. Cancels all irrigation activity.
Rain Hold. Places a rain hold on the controller for a
specified number of days.
Count: The number of times the rain bucket has filled and
"tipped", independent of Alarm status and R_Win setting.
Hr: Possible to go back in hour increments to review the
number of tips during that hour from the current time.
H_Cnt: The number of tips in that hour.
Total: The number of times the rain bucket has filled and
"tipped" in the rain window (R_win above) only when the
alarm is set to On.
6
Typ:RAIN
Status Sensor Configuration
Input : 4
Sw
: Norm Close
Alarm : On
QTime : 10s
RTime : 01m
Act
: Cancel All
Sw: Normally Closed or Normally Open.
Select the correct setting for your sensor.
Alarm: Turn the alarm On or Off for the sensor.
QTime: Qualification time. How long does the alarm
condition (normally closed becoming open, for example)
have to stay in that condition for the alarm to be triggered.
RTime: Reset time. Clears the alarm automactially if
alarm condition no longer exists for that period of time.
Act: If an alarm is triggered, this is the Action that the
controller will take. Possible choices are:
None. The alarm will only alert the operator.
Start Station. Starts a specified station.
Cancel Station. Cancels a specified station.
Cancel All. Cancels all irrigation activity.
Rain Hold. Places a rain hold on the controller for a
specified number of days.
Typ:STAT