Start Station. Starts a specified station.
Cancel Station. Cancels a specified station.
Cancel All. Cancels all irrigation activity.
Rain Hold. Places a rain hold on the controller for a
specified number of days.
PType: The type of pressure sensor installed, typically
defined by the maximum pressure of the sensor. Check
your sensor's documentation for the correct number
(typically 200 psi).
Temperature Sensor Configuration
Input : 7
Min
: 001 C
Max
: 040 C
Unit
: Metric (C)
Alarm : Hi
QTime : 010m
RTime : 015m
Act
: Rain Hold
Hold
: Today
Min: Minimum temperature permitted for operation.
Max: Maximum temperature permitted for operation.
Unit: Select either English or Metric for display of
temperature readings in either Farenheit or Celcius.
Alarm: Select either a high limit alarm (Hi) or a low limit
alarm (Lo). In the Set: field, it is possible to turn the Hi or
Lo alarm On of Off.
QTime: Qualification time. How long does the alarm
condition (max temperature exceeded, for example) have
to stay in that condition for the alarm to be triggered.
RTime: Reset time. Clears the alarm automactially if
alarm condition no longer exists for that period of time.
Act: If an alarm is triggered, this is the Action that the
controller will take. Possible choices are:
None. The alarm will only alert the operator.
Start Station. Starts a specified station.
Cancel Station. Cancels a specified station.
Cancel All. Cancels all irrigation activity.
Rain Hold. Places a rain hold on the controller for a
specified number of days.
Typ:TEMP
Set: On
Flow Sensor Configuration
Input : 2
I_WTW : 06:00pm
O_WTW : 02:00am
I_Min : 00020 gpm
I_Max : 00200 gpm
O_Max : 00010 gpm
Unit
: English(gpm)
Alarm : Hi
QTime : 001m
RTime : 002m
Act
: Cancel All
Make
: Custom
Kval
: 0000.000
Off_s : 00.000
I_WTW: In Water Time Window. Set a time when
watering can begin.
O_WTW: Out Water Time Window. Set a time when
irrigation is no longer permitted.
I_Min: For standalone. Minimum flow rate allowed at the
beginning of the water window.
I_Max: Paired with I_Min. Maximum flow rate allowed
during the water window.
O_Max: Maximum flow rate allowed outside of water
window. One might typically set this value rather low to
help detect valve or sprinkler leaks.
Unit: Select either English or Metric for display of flow
rates in either gallons per minute (gpm) or liters per
minute (lpm).
Alarm: Select either a high limit alarm (Hi) or a low limit
alarm (Lo). In the Set: field, it is possible to turn the Hi or
Lo alarm On of Off.
QTime: Qualification time. How long does the alarm
condition (high flow limit exceeded, for example) have to
stay in that condition for the alarm to be triggered.
RTime: Reset time. Clears the alarm automactially if
alarm condition no longer exists for that period of time.
Act: If an alarm is triggered, this is the Action that the
controller will take. Possible choices are:
None. The alarm will only alert the operator.
Start Station. Starts a specified station.
Cancel Station. Cancels a specified station.
Cancel All. Cancels all irrigation activity.
Rain Hold. Places a rain hold on the controller for a
specified number of days.
Make: Select the manufacturer of the flow sensor.
Choices are Data Industrial, Bermad, or Custom.
Kval: Review your flow sensor's documentation for its
Typ:FLOW