Toro Lynx Manual

Toro Lynx Manual

Golf irrigation products

Advertisement

Golf Irrigation Products
International Markets

Advertisement

Table of Contents
loading

Summary of Contents for Toro Lynx

  • Page 1 Golf Irrigation Products International Markets...
  • Page 2: Table Of Contents

    Irrigation Services DT35/DT55 and DT34/DT54 Series Rotors (National Support Network) B Series Rotors ® Control Systems and Field Controllers Mainless and Back Nozzle Data Lynx™ Central Control System Toro Conversion Assemblies ® SitePro Central Control System R-Series Conversion Assemblies ®...
  • Page 3: Irrigation Services

    For exceptional technical support, e-mail intlirrigationsupport@toro.com Toro Controller Repair Did you know that with Toro’s Board Exchange Program you can get the replacement controller boards you need immediately? Through your distributor, Controller Repair provides controller boards ready for immediate board exchange to assure that controller downtime is minimal and your golf course and reputation stays protected.
  • Page 4: Nsn ® (National Support Network)

    Y o u An Unparalleled Range Of Support Service Solutions At Toro, our top priority is providing you with the best golf irrigation products and then backing them with superior service and support. To keep you and your course on track, our comprehensive service offerings range from installation and training to system optimization, and everything in between.
  • Page 5: Lynx™ Central Control System

    4— CE 7—Network VP 8—Network GDC Example: When ordering a Lynx PE Central with a standard computer and one year of NSN using Network VP field hardware, you would order: LX-01-1-33 * Available only in PE and CE levels ** Network VP and VP...
  • Page 6: Sitepro ® Central Control System

    • Selectable program upload information • Microsoft® Windows XP Professional™ compatible • User-definable names vs. system defaults • Toro Repeat & Soak assigned by program or station: • Up to 3 repeats per program SitePro 3.0 Network VP Support • Up to 24 starts per program •...
  • Page 7: Turf Guard ® Soil Monitoring System

    TG-Turf Guard S2-R-Sensor, Replaceable Battery AU-915.5 to 927.5 MHz Band B-Base Station EX-900 MHz ISM Band R-EXT-Repeater, External EU-869 MHz ISM Band R-INT-Repeater, Internal PS-Power Supply Note: Not available in all locations, please check with your Toro representative for availability.
  • Page 8: Prism

    PRISM Software, 1 Year NSN Support (1st Unit) 676-27* PRISM Software, 1 Year NSN Support (2nd Unit) 676-28* PRISM Software, 1 Year NSN Support (Units 3–5) *Only available to customers who have purchased an iPAQ through Toro NSN T.Weather with WeatherLogic ® ®...
  • Page 9: Hand-Held Radio Interface

    Field Interface Unit with 2 Wire Lines and 1 Radio Line, Radio Not Included FIU-2021R Field Interface Unit with 2 Wire Lines and 1 Radio Line, Radio Included Note: FCC license required. R-models not available in all locations, please check with your Toro representative for availability.
  • Page 10: Network Vp ® Satellites

    201-24P6A4 Radio option not available in all locations, please check with your Toro representative for availability. S p e c i f y i n g I n f o r m a t i o n — N e t w o r k L T C P l u s U p g r a d e K i t...
  • Page 11: Network Vp E Satellites

    Example: When ordering a 24-station, 2-way wire VP Satellite in a plastic cabinet with large-capacity terminal block, additional surge and switches, you would specify: 100-24P6M4 Radio option not available in all locations, please check with your Toro representative for availability.
  • Page 12: Network Ltc ® Plus Satellites

    (up to 6) • 1,09 amps @ 115 V ac, 60 Hz (max load) • Patented Toro Hot Post for easy valve activation and • 0,15 amps @ 230 V ac, 50 Hz (no load) identification •...
  • Page 13: Toro Gdc System

    8— Network GDC SP—SitePro 1—Standard Computer 5—5-years NSN (Site Pro only) 3— PE 4—Premium Computer (Site Pro only) 4— CE Example: A Lynx PE standard computer with 1-year of NSN and GDC System field hardware would be specified as: LX-01-1-38...
  • Page 14 System configuration options: One size does not fit all. And one type of control system design is not the best for all applications. Whether it’s lowering system costs, reducing field wire or splices, or providing easy access to system components, the GDC system offers a variety of configuration options to best fit your objectives.
  • Page 15: Comparison Chart

    Sprinkler C o m p a r i s o n C h a r t Model 835S/855S DT35/DT55 DT34/DT54 B Series Page Number 13-30m 13-28m 16-30m 13-29m 27m-33m Radius (42’-100’) (43’-92’) (52’-99’) (42’-95’) (87’-108’) 14-16m 10,4-15m Short Radius (mainless) (46’-51’) (34’-50’) Radius Reduction Screw...
  • Page 16: 835S/855S Series Rotors

    835S/855S Series Features • Trajectory 24 positions from 7 to 30 degrees in 1 degree increments. • Spike-guard solenoid with 20,000 volt lightning rating. • Arc adjustment - 40 - 330 degrees and true full-circle in one. • Ratcheting riser allows adjustment with no disassembly. Operating Specifications •...
  • Page 17 855S-5558 855S-59 Not recommended at these pressures, Radius shown in meters, Toro recommends the use of a 11⁄4" (30mm) swing joint at flows over 25‑GPM (95‑LPM), Sprinkler radius of throw per ASAE standard S398,1, ■ 855S Series Performance Chart —(U.S.)
  • Page 18 835S/855S Trajectory Performance —(Metric) Nozzle/Bar/LPM #31/51 Nozzle @ 4,5 Bar #32/52 Nozzle @ 4,5 Bar Trajectory 7° 10° 15° 20° 25° 30° 7° 10° 15° 20° 25° 30° "A" Radius 14,0 14,0 15,2 15,5 16,2 16,5 15,2 14,0 14,9 14,9 15,2 15,5 16,8 19,2 19,5 16,5 19,8...
  • Page 19: Dt35/Dt55 And Dt34/Dt54 Series Rotors

    DT35/DT55 Series Features • Dual trajectory adjustment of the main nozzle—25° or 15° • Part and full circle in one – 40° – 330° and true uni- directional full circle • Stainless steel valve seat is molded to the body and has virtually eliminated body replacements due to seat damage Operating Specifications •...
  • Page 20 DT34/DT54 Series Features • Dual trajectory adjustment of the main nozzle—25° or 15° • Constant velocity full circle drive • Stainless steel valve seat is molded to the body and has virtually eliminated body replacements due to seat damage Operating Specifications •...
  • Page 21 DT35-3537 Not recommended at these pressures. ■ Toro recommends the use of a 1 ⁄ " swing joint at flows over 25-GPM (95-LPM). Sprinkler radius of throw per ASAE standard S398.1. All sprinklers are equipped with the selectable pilot valve that allows settings at 50, 65, 80 and 100 psi.
  • Page 22 DT55-59 Not recommended at these pressures. ■ Toro recommends the use of a 1 ⁄ " swing joint at flows over 25-GPM (95-LPM). Sprinkler radius of throw per ASAE standard S398.1. All sprinklers are equipped with the selectable pilot valve that allows settings at 50, 65, 80 and 100 psi.
  • Page 23 DT34-3537 Not recommended at these pressures. Radius shown in feet. ■ Toro recommends the use of a 1 ⁄ " swing joint at flows over 25-GPM (95-LPM). Sprinkler radius of throw per ASAE standard S398.1. All sprinklers are equipped with the selectable pilot valve that allows settings at 50, 65, 80 and 100 psi.
  • Page 24 DT54-59 Not recommended at these pressures. Radius shown in feet. ■ Toro recommends the use of a 1 ⁄ " swing joint at flows over 25-GPM (95-LPM). Sprinkler radius of throw per ASAE standard S398.1. All sprinklers are equipped with the selectable pilot valve that allows settings at 50, 65, 80 and 100 psi.
  • Page 25: B Series Rotors

    B Series Operating Specifications • Inlet: • 25mm (1”) NPT, BSP or ACME • Radius: • 835B: 13m – 29m (42’– 95’) • DT35B: 13m – 27m (43’– 90’) • DT34B: 17m – 29m (57’– 95’) • Flow Rate: • 835B: 26,8 – 198,7 LPM (7.1 – 52.5 gpm) •...
  • Page 26 Toro recommends the use of a 1 ⁄ " swing joint at flows over 25-GPM (95-LPM). Sprinkler radius data collected in Toro’s zero wind test facility per ASAE standard S398.1. Actual site conditions must be considered when selecting the appropriate nozzle.
  • Page 27 Toro recommends the use of a 1 ⁄ " swing joint at flows over 25-GPM (95-LPM). Sprinkler radius data collected in Toro’s zero wind test facility per ASAE standard S398.1. Actual site conditions must be considered when selecting the appropriate nozzle.
  • Page 28 Toro recommends the use of a 1 ⁄ " swing joint at flows over 25-GPM (95-LPM). Sprinkler radius data collected in Toro’s zero wind test facility per ASAE standard S398.1. Actual site conditions must be considered when selecting the appropriate nozzle.
  • Page 29: Mainless And Back Nozzle Data

    Mainless and Back Nozzle Data 835S Series Mainless Nozzle Performance Data—(Metric) Blue - Plug - Gray Orange - Plug - Gray Red - Plug - Gray Gray - Plug - Gray Gray - Plug - Gray 102-2925 102-2208 102-2910 102-2926 - 102-2208 - 102-2910 102-2928 - 102-2208 - 102-2910 102-2910 - 102-2208 - 102-2910 102-2930 - 102-2208 - 102-2910...
  • Page 30: Toro ® Conversion Assemblies

    Conversion Assembly C h a r t 830S 850S 855S 835S 855S 855RB DT55RB DT54RB Conversion Conversion Conversion Conversion Conversion Conversion Conversion Conversion Conversion Assembly Assembly Assembly Assembly Assembly Assembly, Assembly Assembly Assembly Ribless Body 1” Models Radius Flow DT34-3134 17-24m (57’-79’) 49-132 LPM (13.0-34.9 GPM) DT34-3537...
  • Page 31: R-Series Conversion Assemblies

    Toro® has designed and manufactured this product to fit within a sprinkler housing made by Rain Bird® Corporation, but Toro’s product is not manufactured by or affiliated with Rain Bird. Rain Bird is a registered trademark of Rain Bird Corporation.
  • Page 32 Toro recommends the use of a 1 ⁄ " swing joint at flows over 95-LPM (25-GPM), Sprinkler radius data collected in Toro’s zero wind test facility per ASAE standard S398,1, Actual site conditions must be considered when selecting the appropriate nozzle,...
  • Page 33 Toro recommends the use of a 1 ⁄ " swing joint at flows over 25-GPM (95-LPM). Sprinkler radius data collected in Toro’s zero wind test facility per ASAE standard S398.1. Actual site conditions must be considered when selecting the appropriate nozzle.
  • Page 34: 690 Series Rotors

    690 Series Features • Used in single row applications the 696 2-speed models operate at a slower speed over the 60 degree non-overlap area and a faster speed over the 120 degree overlapped areas to provide a balanced application rate •...
  • Page 35: Dl2000 ® Subsurface Drip

    • Required inlet/outlet fittings • Flush Assembly Fittings 8 GPM (2 psi) sealing flush valve • Installation Fittings: • Includes Toro exclusive Loc-Eze® tees, couplings, elbows and end clamps • 3,1m (10’) of Blue Stripe® polyethylene tubing • Soil staples for secure tubing placement •...
  • Page 36: Sprinkler Tools

    Sprinkler Tools Nut Drivers 995-15 Selector tool • 995-105 5/16” nut driver DT and • All electric golf sprinklers 800S Series Trujectory adjustment on • Allows user to manually turn the 835S/855S models sprinkler “ON”, turn or leave it • Inner, intermediate and back “OFF”...
  • Page 37: Comparison Chart

    Valve C o m p a r i s o n C h a r t Model 220G Series P220G Series Page Number 19-681 LPM 19-1136 LPM Flow Range (5.0-180 GPM) (5.0-300 GPM) 0,7 - 15,2 Bar 0,7 - 15,2 Bar Operating Pressure (10-220 PSI Max) (10-220 PSI Max)
  • Page 38: 220G Brass Series

    220G Series Brass Dimensions • 25mm (1”): 146 x 127mm (5.75” H x 5” W) • 40mm (1.5”): 165 x 152mm (6.5” H x 6” W) • 50mm (2”): 191 x 178mm (7.5” H x 7” W) Operating Specifications 220G‑27‑06 •...
  • Page 39: P220G Series

    P220G Series Dimensions • 25mm (1”): 146 x 127mm (5.75” H x 5” W) • 40mm (1.5”): 165 x 152mm (6.5” H x 6” W) • 50mm (2”): 191 x 178mm (7.25” H x 7” W) Operating Specifications • Flow Range: –...
  • Page 40: Quick Couplers

    S p e c i f y i n g I n f o r m a t i o n — Q u i c k C o u p l e r s Corresponding Toro Model Inlet Size...
  • Page 41: Technical Data

    Depends on variables NONE • Voltage available • Wire size * ‑ All hydraulic connections on Toro valves are ⁄ " insert type. ‑ Control line pressure must be equal to or greater than mainline pressure. ‑ Control line pressure range is 40 to 150 psi.
  • Page 42: Wire Sizing

    Wire Sizing C u r r e n t D r a w ( A m p e r a g e ) Spike Guard Low Wattage Solenoid Standard Wattage Solenoid ™ Assumes 24 VAC, 50/60 Hz Output Assumes 24 VAC, 50/60 Hz Output 120 VAC, 60 Hz 240 VAC, 50 Hz 120 VAC, 60 Hz...
  • Page 43: Warranty

    The Toro Warranty Company, P.O. Box 489, Riverside, California 92502, (800) 664-4740 for the location of your nearest Toro distributor or outside the U.S., call +1 (951) 688-9221. We reserve the right to improve our products and make changes in the specifications and designs without notice and without incurring obligation.
  • Page 44 Phone: (1) 952 888 8801 Fax: (1) 952 887 8258 www.toro.com GB Printed in U.S.A. ©2011 The TORO COMPANY All Rights Reserved. Form #200-4997 Products depicted are for illustration purposes only. Actual product offered for sale may vary in design, required attachments, and safety features. Not all products are sold in all countries.

Table of Contents