Download Print this page

Advertisement

Quick Links

Document No:
Title:
Confidential Property of
Riverside, California
Release/Change Authorization Number:
Rev.
ECM No.
A
5121941
B
5124824
C
5126326
D
5134588
E
513
F
5157950
CV
373-0918
Rev:
Instruct, Install, Smart Sat Sensor Brd
Approx Weight:
Similar To:
5157950
To be printed in gray scale.
See subsequent pages for
original PDF
Description of Change
Release to rev A
Sensor configuration and data review added
for both Local Mode and Lynx
Changed "last slot" wording, top of p. 2
Quite a few edits from Andy Strother
A few more edits
Added power connector instructions
F
Issue Date :
0.05
lbs
REVISION SHEET
Richard Keightley
Richard Keightley
Richard Keightley
Richard Keightley
Richard Keightley
Richard Keightley
4/13/2020
Page:
Richard Keightley
Originator :
Riverside
Originating Location:
Supersedes:
Drafter
Date
01/24/2017
5/04/17
6/07/17
3/20/18
3/21/18
4/13/20
1
Approved
By
Dat Nguy
Andy Strother
Andy Strother
Andy Strother
Andy Strother
Andy Strother

Advertisement

loading

Summary of Contents for Toro Lynx Smart Satellite Sensor Kit

  • Page 1 373-0918 4/13/2020 Document No: Rev: Issue Date : Page: Title: Instruct, Install, Smart Sat Sensor Brd Richard Keightley Originator : Confidential Property of 0.05 Riverside Approx Weight: Originating Location: Similar To: Supersedes: Riverside, California 5157950 Release/Change Authorization Number: To be printed in gray scale. See subsequent pages for original PDF REVISION SHEET...
  • Page 2 Lynx Smart Satellite Sensor Kit Installation and User Guide The Lynx Smart Satellite Sensor (LSSS) Kit receives data A handful of satellites will need a firmware update from flow, temperature, and pressure sensors, as well as to take advantage of the Lynx Smart Satellite Sensor switches and rain buckets.
  • Page 3 Toro supplies a sticker to label the final 8 stations in your system. For example, if your satellite has one station output board (16 stations), the sensor board would include stations 17 through 24 and the 17 through 24 station label should be applied.
  • Page 4 PVC jacket. Pressure Sensor Toro sells a pressure sensor kit (part number PRESS200- SEN-KIT), composed of a 6’ long sensor cable and a pressure sensor. Steps 1. At the LSSS board, secure the pressure sensor’s black lead to screw IN 1 and white lead to screw 12V (see Terminals Explained illustration above).
  • Page 5 TERMINAL. That will short the power to FLOW 1” the controller. The Toro temperature sensor will be available in late 2017. Temperature Sensor A temperature sensor must be connected to the Temperature Probe Connection port. See Sensor Input Board Overview on page 1 for port location.
  • Page 6 Flow Sensor Configuration • Start Station. Starts a specified station. • Cancel Station. Cancels a specified station. Input : 2 Typ:FLOW • Cancel All. Cancels all irrigation activity. I_WTW : 06:00pm • Rain Hold. Places a rain hold on the controller for a O_WTW : 02:00am specified number of days.
  • Page 7 Status Sensor Configuration correct K Value. Off_s: Review your flow sensor’s documentation for its Input : 4 Typ:STAT correct Offset value. : Norm Close Alarm : On PPG (if Bermad selected): Pulse per gallon based on flow QTime : 10s meter wiring.
  • Page 8 Press the Stop button to cancel the reset. Celcius Firmware Version A handful of satellites will need a firmware update to take advantage of the Lynx Smart Satellite Sensor Kit. To check your satellite’s firmware: 1. Press the Diagnostic button.
  • Page 9 Sensor Configuration - Lynx Sensor configuration can either be done at the satellite in Local Mode or at a Central computer running Lynx. If communication is established between a satellite and a Lynx system, the Lynx system will overwrite all locally defined sensor configuration information. Meaning, if operating a Lynx system, the sensors must be configured with Lynx.
  • Page 10 7. Select the desired sensor from the dropdown list. Figure 4 Enter the various limits and Qualification times (Figure 3). For an explanation of these terms, please see the Sensor Configuration section above. Checking the Use Local Response checkbox turns on a switch in the satellite containing the sensor board for a timed duration.
  • Page 11 Neither Toro nor Toro Warranty Company is liable for indirect, All implied warranties, including those if merchantability and incidental or consequential damages in connection with the...

This manual is also suitable for: