Status line

The top line of the LCD display shows the basic status information of the drive.
LOC
1
2
No. Field
1 Control location
2 State
3 Panel operation
mode
4 Reference value
or number of the
selected item
30.00rpm
4
Alternatives
LOC
REM
Rotating arrow
Dotted rotating arrow
Stationary arrow
Dotted stationary arrow
LOC
MAIN MENU
1
2
3
Significance
Drive control is local, that is, from the control
panel.
Drive control is remote, such as the drive I/O or
fieldbus.
Forward shaft direction
Reverse shaft direction
Drive is running at reference point.
Drive is running but not at reference point.
Drive is stopped.
Start command is present, but the motor is not
running, e.g. because start enable is missing.
• Name of the current mode
• Name of the list or menu shown
• Name of the operation state, e.g. REF EDIT.
• Reference value in the Output mode
• Number of the highlighted item, e.g mode,
parameter group or fault.