Samsung SPE-400 User Manual page 21

Network encoder
Hide thumbs Also See for SPE-400:
Table of Contents

Advertisement

Connecting to the I/O port box
Connect the Alarm I/O signal to the corresponding port of the rear port box.
Port
D+(1~4) RS-485 Data Line
D-(1~4)
RS-485 Data Line
S1~S4
Alarm In
Connecting to the RS-485 device
Connect the external device to the [RS-485 D+, D-] ports.
You can connect and control PTZ camera that supports RS-485 communication.
Depending on camera's type, connection polarity can be different.
For further information, refer to the corresponding PTZ Camera's documentation.
Connecting to the Alarm Input
Connect one signal cable (out of 2) of applicable sensor to the [S1] port, and the other to
the [G] port.
Connecting the Alarm Output
Connect one signal cable (out of 2) of applicable external device to the [RELAY OUT], and
the other to the [CM] port.
M
You must use the specifi c RS-485 alarm I/O ports for each channel.
D1+ D1- D2+ D2- D3+ D3- D4+ D4- G S1 S2 S3 S4 G
R1 CM1 R2 CM2 R3 CM3 R4 CM4
ETHERNET
RS-485
SENSOR
D1+ D1- D2+ D2- D3+ D3- D4+ D4- G S1 S2 S3 S4 G
RS-485
SENSOR
Description
SD
POWER
+
-
SD CARD (CH1)
DC 12V
RELAY OUT
R1 CM1 R2 CM2 R3 CM3 R4 CM4
RELAY OUT
Port
R1~R4
Alarm Relay Output
CM1~CM4 Alarm Out (Common)
G
GND
Description
English _21

Advertisement

Table of Contents
loading

Table of Contents