BRAND: Yaesu
TYPE: G-650C, G-800(any), G-1000(any), G-2700(any), G-2800(any), G-5500DC (AZ part)
Factory cable connects rectangular ROTATOR (10) connector
Rotator tab settings:
PARAMETER
VALUE
SENSOR
POT 500 Ω
MOTOR
DC (reversible)
POWER
24 V
BRAKE
NO
TOTAL ROTATION 450
LIMIT SWITCHES
YES
BRAND: Yaesu
TYPE: G-450C (G-450ADC, G-450CDC)
Factory cable connects rectangular ROTATOR (10) connector
Rotator tab settings:
PARAMETER
VALUE
SENSOR
RHEO 500 Ω
MOTOR
DC (reversible)
POWER
24 V
BRAKE
NO
TOTAL ROTATION 450
LIMIT SWITCHES
YES
BRAND: Yaesu
TYPE: G-400
Rotator tab settings:
PARAMETER
VALUE
SENSOR
POT 500 Ω
MOTOR
AC
POWER
24 V
BRAKE
NO
TOTAL ROTATION 370
LIMIT SWITCHES
YES
microHAM © 2021 All rights reserved
Rotator connection to 10 pin ROTATOR (9) terminal:
ROTATOR
WIRE
POT HI
WIPER
POT LO
CW
CCW
Rotator connection to 10 pin ROTATOR (9) terminal:
ROTATOR
WIRE
WIPER
POT LO
CW
CCW
If you are using rectangular connector (10) for rotator
connection,
rotator terminal.
Rotator connection to 10 pin ROTATOR (9) terminal:
ROTATOR
WIRE
POT HI
WIPER
POT LO
CCW
CW
COM
30
ARCO
PIN
NAME
1
SENSOR HI
2
SENSOR C
3
SENSOR LO
4
MOTOR A
5
MOTOR C
ARCO
PIN
NAME
2
SENSOR HI
3
SENSOR LO
4
MOTOR A
5
MOTOR C
short pins 2 + 3 together
ARCO
PIN
NAME
1
SENSOR HI
2
SENSOR C
3
SENSOR LO
4
MOTOR C
5
MOTOR A
6
MOTOR D
PIN
3
2
1
6
4
PIN
3
1
6
4
on green ARCO
PIN
3
2
1
4
6
5