Training system mMS 4.0 | R901429162/04.16
Entire installation (3 Stations)
The following aspects must be satisfied to operate the entire installation:
The transfer connectors for signals and emergency stop circuit must
be connected to both the stations on the right and left.
With the first and last station, the terminating connectors must be plugged
into the transfer connectors for signals and emergency stop circuit as for
the individual stations.
If not, plug the terminating connector/-socket into the transfer module.
The emergency stop circuit of the installation is not closed until the terminating
connector/socket are plugged into the transfer connector and the stations
are connected to each other.
Fig. 25:
Connecting the transfer and terminating connectors
The power supply connectors must be connected to the left-hand station.
With the left-hand station, the connection cable must be connected to the
current cable with an earthing-pin plug and can be connected to 110-230V AC.
Fig. 26:
Connecting the power supply
Bosch Rexroth AG
Set-up, installation and commissioning
51/68