Synchronous Servomotors MSK For Potentially Explosive Areas
4.2
Conditions for Use of MSK Motors according to ATEX Classi‐
fication, Equipment Group II, Category 3.
Notes about test number
Cable type ready-made RKL...
0014, 0019, 0053, 4302, 4303, 4305
0015, 0016, 0017, 0045, 0050, 0054, 4300, 4301, 4304, 4306, 4307, 4320, 4325
0018, 0051, 0052, 4308, 4309, 4310, 4312, 4321, 4326, 4343
0056, 0058, 4313, 4314, 4315, 4316, 4322, 4327
0049, 0055, 4317, 4318, 4319, 4323, 4328
DANGER
All used components and accessory parts must fulfill the requirements for ex‐
plosion protection according to the 2014/34/EU directive.
The conditions on use given in this documentation must be taken into ac‐
count for any project planning and be observed during operation.
The Ex designation for MSK motors can be identified by the "X" at the end of
the type plate or declaration of conformity. Please observe the following spe‐
cial conditions for a safe operation of the motors in your construction:
The permissible ambient temperature range is 0 ... 40°C. Higher ambi‐
ent temperatures up to max. 55 °C are allowed at corresponding derat‐
ing
chapter 10.1.1 "Installation altitude and ambient temperature" on
page
115.
Servicing and repairs are only permitted by the certified Rexroth service.
It is not allowed to exceed the specified values of the tensile loading via
cables which are connected via connectors. The maximum allowed val‐
ues are determined in the following context.
F
Tensile load of connection cable (maximum value)
Z max
D
Diameter cable outer jacket (maximum value)
Fig. 4-2:
Determination of maximum tensile load of connection cables
WARNING
Adherence of specified limits.
Mechanical fastening of cable ends (e.g. use cable clamps after approx. 30
cm, ...).
The following maximum tensile load must be kept when using ready-made
cables.
Bosch Rexroth AG
Explosion protection for MSK motors
Danger of explosion and life or high damage
to property!
Danger of explosion due to exalted tensile
load of connection cables
Raw cable INK... F
0653 (1.0 mm²)
0650 (1.5 mm²)
0602 (2.5 mm²)
0603 (4.0 mm²)
0604 (6.0 mm²)
25/175
[N]
Z max
62.5
63.5
79
87.5
97.5