Synchronous servomotors for potentially explosive areas

Advertisement

12/175
Bosch Rexroth AG
Important instructions on use
2.2
Inappropriate use
Synchronous Servomotors MSK For Potentially Explosive Areas
Device types with different driving powers and different interfaces are availa‐
ble for an application-specific use of the motors.
Controlling and monitoring of the motors may require connection of additional
sensors and actuators.
MSK-ATEX motors may only be used with the accessories speci‐
fied in this documentation. Components that are not explicitly
mentioned may neither be attached nor connected. The same is
applicable for cables and lines.
Operation is only allowed in the explicitly mentioned configura‐
tions and combinations of the component and with the software
and firmware specified in the corresponding functional descrip‐
tion.
Any connected drive controller must be programmed before startup in order
to ensure that the motor executes the functions specifically to the particular
application.
MSK-ATEXThe motors may only be operated under the assembly, mounting
and installation conditions, in the normal position, and under the environmen‐
tal conditions (temperature, degree of protection, humidity, EMC etc.) speci‐
fied in this documentation.
Any use MSK-ATEXof motors outside of the fields of application mentioned
above or under operating conditions and technical data other than those
specified in this documentation is considered as "non-intended use".
MSK-ATEX motors may not be used if . . .
ambient conditions at the installation location requires a higher explo‐
sion protection than indicated at the motor type plate.
they are subject to operating conditions which do not comply with the
ambient conditions described above; for example, they may not be oper‐
ated under water, under extreme temperature fluctuations or extreme
maximum temperatures;
the intended application is not explicitly released by Bosch Rexroth.
Please be absolutely sure to comply with the instructions given in the
general safety instructions!
DOK-MOTOR*-MSK*EXGIIK3-PR09-EN-P